1-6.

INITIALIZATION OF DATA

1. Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note: If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
[Sector Write]
2) Click
on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is "0A".
[All]
4) Click
of the ALL SELECT buttons to select all pages.
(Fig. 6-1-44 A)
[Write]
5) Click
to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
[Close]
7) Click
to close the SEUS SECTOR WRITE screen.
[Save]
8) Click
on the SEUS screen.
9) Select page: 80, address: 34, and check that the data is "00".
10) Select page: 80, address: 30, and check that the data is "00".
11) Perform "Initial Language Data Check".
Processing after Completing Initializing
Order Page Address
1
40
28
01
Note: At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
"disconnect" state, but this is not a trouble. Click
nect]
on the SEUS screen to restore the "connected" state.
(In case that the power does not turn on again, press the
power button.)
B
A
Fig. 6-1-44
DSC-S600_ADJ
Data
Procedure
[Set]
(Note)
0A
2. Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1: If the 6D or 6E or 6F page data have been initialized, the
following adjustment needs to be performed again.
1) Camera system adjustments
Note 2: If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
[Sector Write]
2) Click
SECTOR WRITE screen.
3) Check that the SET ID is "0A".
4) Click "All" of the option buttons of target page. (Fig. 6-1-44
B)
[Write]
5) Click
of the camera.
6) Wait for 3 sec.
[Close]
7) Click
[Save]
8) Click
9) Select page: 80, address: 34, and check that the data is "00".
10) Select page: 80, address: 30, and check that the data is "00".
11) When 4F page is initialized, perform "Initial Language Data
Check".
Processing after Completing Initializing
Order Page Address
1
40
[Con-
Note: At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
"disconnect" state, but this is not a trouble. Click
nect]
on the SEUS screen to restore the "connected" state.
(In case that the power does not turn on again, press the
power button.)
6-20
on the SEUS screen to display the SEUS
to write the initializing data to the flash memory
to close the SEUS SECTOR WRITE screen.
on the SEUS screen.