Troubleshooting - Lennox Hearth Products Ravelle 30 Installation And Operation Manual

Direct-vent gas fireplace heater dave lennox signature collection
Table of Contents

Advertisement

TROUBLESHOOTING

NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in
the "ON" position.
IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting
should only be accomplished by a qualified service technician.
SYMPTOM
Thin black coating (soot)
forms on the viewing
glass, logs, or firebox
Humming or whistling
coming from fireplace.
A change in flame appear-
ance or burner operation.
Spark igniter will not light
pilot after repeated tries.
Pilot will not stay lit after
carefully following lighting
instructions.
Main burner will not burn.
30
PROBABLE CAUSE
Improper log or ember
See Log Set Installation on Page 19. If there is soot in one specific location, the
placement
rockwool below this location needs to be adjusted. This can be done by pulling embers
forward slightly. If the flames have soot tails, the shutter will need to be opened.
Improper air shutter
setting
If sooting continues open air shutter (see Air Shutter Adjustment on Page 25).
Not enough combus-
Check for debris obstructing air flow in valve compartment under fireplace or in front of
tion air
lower venting.
Normal operating noise
See Quiet Operation on Page 26. The noise may be reduced by slightly turning down the
flame. Turning the flame down will reduce the heat output of the fireplace.
Obstructed orifice
If noise is excessive or is "whistling" have your gas supplier check the regulator and
opening
orifices and replace if necessary.
A change in gas pres-
Have your gas supplier check for correct gas pressure (7" W.C. / po. C.E. [1.74 kPa] natu-
sure
ral gas; 11" W.C. / po. C.E. [2.74 kPa] LP gas). NOTE: NEVER BLOCK OR OBSTRUCT AIR
INTAKE OR OUTLET VENTS.
Improper log, ember or
See Log Set Installation on Page 19.
volcanic stone place-
ment
No gas supplied to unit
Check gas supply. To purge, hold in gas cock on valve for 1-2 minutes and try again.
or air in line
Defective igniter (no
Check for spark at electrode and pilot, if no spark and electrode wire is properly con-
spark at electrode)
nected, replace igniter and igniter wire.
Defective or misaligned
Using a match, light pilot. If pilot lights, turn off pilot and trigger the igniter again. If pilot
electrode at pilot (spark
lights, an intermittent gas/air supply may be the problem, if longer purge will not light
at electrode)
- check gap between electrode and pilot - should be 1/8 inch (3 mm) to have a strong
spark. If OK, replace pilot.
Low gas inlet pressure
Check inlet pressure and adjust pilot if necessary.
Defective thermopile
Be sure wire connections from thermopile are tight at gas valve terminals.
Either rocker switch or thermostat wires may be grounded. Remove wires from valve
terminals. If pilot stays lit, trace switch wiring for a ground. May be grounded to fireplace
or gas supply.
Defective automatic
Check open circuit millivolt output of thermopile. Reading should be greater than 325mV.
valve operator
Also check thermopile wire for kinks that can cause loss of mV. Replace faulty thermopile
if wire is okay and reading is less than 325mV.
Turn valve knob to "ON" and thermostat (if installed) to 90º. Millivolt meter should read
greater than 100 mV. If reading is OK and burner does not turn on, replace gas valve
(qualified service technician only).
Pilot has gone out
See Lighting Instructions.
Rocker switch, thermo-
Disconnect rocker switch and thermostat wires at terminals 1 and 3 on valve. Jumper
stat, or wires defective
across from 1 to 3 with pilot lit. If burner comes on either rocker switch, thermostat, or
wiring is not functioning.
Thermopile may not be
Check thermopile with millivolt meter (see Maintenance and Servicing), recheck symp-
generating sufficient
tom #2.
millivolts