Automatic combustion control (acc)
Table of Contents

Advertisement

R
In USA a minimum 5 foot length, 6 inch diameter flue liner is required, however Hearth & Home Technologies
strongly recommends a full reline for optimum performance.
UL 1777 Insulated Stainless Steel
Liner or Other Approved Lining System
Follow Manufacturer's Instructions
on Insulation and Support
For Zero or Other Non-Code Clearances,
Follow Approved Liner Manufacturer's Specific
Insulation Requirements: Different Clearances
May Require Different Specifications
Masonry Chimney Must
Have Structural Integrity
UL 1777 Insulated Stainless Steel
Liner or Other Approved Lining System
Minimum 8 in. (203mm) Masonry
Thickness in Front of Smoke Chamber
Minimum Clearance in Accordance
Floor Protection in
Accordance with Insert
Figure 17.1 - Masonry Chimney with a Full Liner Kit Type
The flue crimp must be cut so the swage
(half-moon bulge after the crimp) fits
tightly into the spigot.
April 29, 2013
with Insert Listing
Listing
Combustible Floor
NOTE: Generic wood insert shown - not model specific
Follow Manufacturer's
Instructions for Maximum
Liner Extension Above
Chimney
Maximum 30 Degrees
Offset in Chimney
Damper Plate Removed or
Fastened in Open Position
Seal with Non-Combustible Material