HP -UX 11i v2 Support Manual page 19

Fibre channel mass storage adapters with fibrchanl-02 (fclp) driver
Hide thumbs Also See for HP-UX 11i v2:
Table of Contents

Advertisement

Table 2-3 Hardware Path Field Descriptions (continued)
Field
Value
Target
Depends on the Fibre
Channel topology and
the LUN addressing
method used.
LUN
Depends only on the LUN addressing method used.
LUN Addressing Method
Peripheral Device Addressing
Logical Unit Addressing
Volume Set Addressing (Flat Space
Addressing)
For more information about the fields in the Logical Unit Number, please see the SCSI Architecture
Model - 3 (SAM-3) standards document.
Fibre Channel Topology of HBA
Fabric Topologies
For LUNs with Peripheral Device
Addressing, the value of this field is the
lower 4-bits of the third byte of the
N_Port ID of the target device. This field
usually corresponds to the Arbitrated
Loop Physical Address (AL_PA) of the
target device.
For LUNs with Logical Unit Addressing, the value is the Target field of the
LUN. For LUNs with Volume Set Addressing (Flat Space Addressing), the value
Value of LUN field in Fibre Channel hardwarePath.
The Target or LUN field of the Logical Unit Number.
The LUN field of the Logical Unit Number.
Bits 0 - 2 of the Logical Unit Number.
Private Loop
With Peripheral Device Addressing,
the value of this field is the lower
4-bits of the Loop ID of the target
device.
is bits 3 - 6 of the LUN.
Interpreting Hardware Paths
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp-ux 11i v3

Table of Contents