Control — MLS Switcher
MLC/IR
A B C
Rear Panel
MLC/IR port
on MLS Switcher
Heat Shrink
Over Ground
or Drain Wires
NOTES:
• You must connect a ground wire
between the MLC and MLS.
• If you use cable that has a drain wire,
tie the drain wire to ground at both ends.
Ground ( )
B Receive (Rx)
Transmit (Tx)
A
Transmit (Tx)
Receive (Rx)
MLC
Bottom
A
A
Panel
IR/SERIAL OUT
IR/SERIAL OUT
Select RS-232 protocol via software or SIS
command. Signals are bidirectional, ±5 V.
RS-232 default protocol:
• 9600 baud • 8 data bits
• no parity
Control — LAN (Ethernet)
Straight-through Cable
(for connection to a switch, hub, or router)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange
1
white-orange
2
orange
2
orange
3
white-green
3
white-green
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
green
7
white-brown
7
white-brown
8
brown
8
brown
Both ends use the TIA/EIA T568A wiring standard.
Crossover Cable
(for direct connection to a PC)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange
1
white-green
2
orange
2
green
3
white-green
3
white-orange
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
orange
7
white-brown
7
white-brown
8
brown
8
brown
Wire end 1 following the TIA/EIA T568A wiring standard,
wire end 2 with the T568B wiring standard.
B
A
S
S
S
S
A B
B
B
C
C
MLS PWR
PWR
L L
RS-232
12V
12V
MLS Switcher RS-232 Port
• 1 stop bit
• no flow control
Pins:
12345678
RJ-45
Connector
PC
Insert Twisted
Pair Wires
TCP/IP
Network
Power
Power Input
• Connect to 12 VDC, 1 A power supply.
• Check the polarity of the power supply
wires before connecting it to the MLC.
• Front panel buttons light when the
MLC receives power.
S
S
S
S
A B
A B
Bottom
Panel
B
B
C
C
IR/SERIAL OUT
IR/SERIAL OUT
L L
MLS
MLS PWR
RS-232
RS-232
12V
MAC: 00-05-A6-XX-XX-XX
S/N:
Left Panel
Link LED:
Lights to
indicate
a network
connection.
Activity LED:
Blinks to indicate
data is being sent
or received.
Ground
12 VDC
(ridged)
(smooth)
Ground ( )
+12 VDC Input
External
Power Supply
(12 VDC, 1 A max.)
Ground all devices.
MAC Address
(on top, and on front panel)
Ethernet (LAN)
Connect to an Ethernet network with a
straight through cable. This port must be
configured.
Default protocol:
• MLC IP address: 192.168.254.254
• Gateway IP address: 0.0.0.0
• Subnet mask: 255.255.0.0
• DHCP: off
• Link speed and duplex level: autodetected
NOTE: You must use this
LAN port to set up the MLC
and upload GC configuration
files and firmware.
All configuration can be
performed via this port.
3/16"