Important Installation and Utility Information

Electrical Service:
110V:
A 110V, 60 Hz, 15 Amp GFCI protected grounded circuit must be used to supply power
to the pedicure spa. (220V if ordered in 220V configuration)
220V:
A 220-240VAC, 50Hz, 7.5 Amp GFCI protected grounded circuit must be used to supply
pow er to the pedicure spa per local code.
Water Supply:
All plumbing connections must conform to local codes.
Nor mal w ater pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level.
The hot w ater supply temperature must not exceed 150
accordingly.
For hot and cold w ater supply fittings and pow er drain fittings location, see figure 1 below .
Carefully connect the incoming w ater supply lines to the appropriate fittings located on the back of the
pedicure spa. Shut-off valves are recommended.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply w ith
ANSI/ASME A112.18.3M, A112.18.1M, and CSA B125
ANSI/ASME A112.18.3M (Performance Requirements for Backflow Protection Devices and Systems in
Plumbing Fixture Fittings) is applicable to plumbing fixture fittings w ith outlets not protected by an air
gap. Included in the possible range of applications are fittings w ith hose connected outlets, fittings w ith
pullout spout, hand held show ers, shampoo fittings and deck- mounted fittings. ASME A112.18.3M is
now referenced in ASME A112.18.1M ( Plumbing Fixture Fittings) and CSA B125. Check valves are
listed to both standards w ith the Canadian Standards Association, IAPMO and UL.
ANSI - A merican National Standards Institute
ASME - American Society of Mechanical Engineers
CSA - Canadian Standards Association
IAPMO - International Association of Plumbing and Mechanical Officials
UL - Underw riters Laboratory
The pedicure spa drain must meet local plumbing codes. Check valve for drain (not provided) must
be installed by a licensed plum ber.
Pedicure spa must be securely fastened to the floor as shown in figure 2 below . Fasten the pedicure
spa to the floor w ith at least tw o fasteners, one in the middle plastic support and one in the rear plastic
support.
Back of Pedicure Spa
Figure 1
Document ID:06080001
Rev: E
Technical Support: 800-626-6912
°
°
F (65
C). Adjust your hot w ater heater
Figure 2
Install Fasteners Here
Page 8 of 24