Important Installation And Utility Information - European Touch Solace FORTE' Owner's Manual

Table of Contents

Advertisement

Important Installation and Utility Information

Electrical Service:
A 110V, 60 Hz, 15 Amp GFCI protected grounded circuit must be used to supply power to the
pedicure spa. (220V if ordered in 220V configuration)
Water Supply:
All plumbing connections must conform to local codes.
Normal water pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level.
The hot water supply temperature must not exceed 150
accordingly.
For hot and cold water supply fittings and power drain fittings location, see figure 1 below.
Carefully connect the incoming water supply lines to the appropriate fittings located on the back of the
pedicure spa. Shut-off valves are recommended.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply with
ANSI/ASME A112.18.3M, A112.18.1M, and CSA B125
ANSI/ASME A112.18.3M (Performance Requirements for Backflow Protection Devices and Systems
in Plumbing Fixture Fittings) is applicable to plumbing fixture fittings with outlets not protected by an
air gap. Included in the possible range of applications are fittings with hose connected outlets, fittings
with pullout spout, hand held showers, shampoo fittings and deck-mounted fittings.
A112.18.3M is now referenced in ASME A112.18.1M (Plumbing Fixture Fittings) and CSA B125.
Check valves are listed to both standards with the Canadian Standards Association, IAPMO and UL.
ANSI - American National Standards Institute
ASME - American Society of Mechanical Engineers
CSA - Canadian Standards Association
IAPMO - International Association of Plumbing and Mechanical Officials
UL - Underwriters Laboratory
The pedicure spa drain must meet local plumbing codes. Check valve for drain (not provided)
must be installed by a licensed plumber.
Pedicure spa must be securely fastened to the floor as shown in figure 2 below. Fasten the pedicure
spa to the floor with at least two fasteners, one in the middle plastic support and one in the rear
plastic support.
Back of Pedicure Spa
Figure 1
Document ID:06080001
Rev: B
Technical Support: 800-626-6912
°
°
F (65
C). Adjust your hot water heater
Install Fasteners Here
Figure 2
ASME
Page 7 of 24