D. Vent Diagrams
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles between ceiling fi restops.
• ALWAYS maintain specifi ed clearances around venting and fi restop systems.
• Install wall shield and ceiling fi restops as specifi ed.
Failure to keep insulation or other material away from vent pipe may cause fi re.
1. Top Vent - Horizontal Termination
One Elbow
Figure 5.3
Two Elbows
H
2
Figure 5.4
16
H
1
H
1
INSTALLED
HORIZONTALLY
Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. i • 6/09
WARNING
Cerona-36 ONLY
V
1
Note: Must have
a minimum verti-
cal vent before
attaching a 90º
elbow to the unit.
See chart.
Cerona-36 ONLY
V
1
Note: Must have
a minimum verti-
cal vent before
attaching a 90º
elbow to the unit.
See chart.
V
Minimum
H
Maximum
1
1
1/2 ft
152 mm
2 ft
1 ft
305 mm
2 ft
2 ft
610 mm
5 ft
3 ft
914 mm
8 ft
4 ft
1.2 m
11 ft
5 ft
1.5 m
14 ft
6 ft
1.8 m
17 ft
7 ft
2.1 m
20 ft
8 ft
2.4 m
23 ft
V
= 40 ft. (12.2 m) Maximum
1
H
= 23 ft. (7.0 m) Maximum
1
V
+ H
= 63 ft. (19.2 m) Maximum
1
1
Minimal Vertical Vent
Model
Cerona-36
Cerona-42
V
Minimum
H
+ H
1
1
1/2 ft
152 mm
2 ft
1 ft
305 mm
2 ft
2 ft
610 mm
5 ft
3 ft
914 mm
8 ft
4 ft
1.2 m
11 ft
5 ft
1.5 m
14 ft
6 ft
1.8 m
17 ft
7 ft
2.1 m
20 ft
8 ft
2.4 m
23 ft
V
+ H
+ H
= 63 ft. (19.2 m) Maximum
1
1
2
H
+ H
= 23 ft. (7.0 m) Maximum
1
2
Minimal Vertical Vent
Model
Cerona-36
Cerona-42
610 mm
610 mm
1.5 m
2.4 m
3.4 m
4.3 m
5.2 m
6.1 m
7.0 m
ft.
mm
1/2
152
1
305
Maximum
2
610 mm
610 mm
1.5 m
2.4 m
3.4 m
4.3 m
5.2 m
6.1 m
7.0 m
ft.
mm
1/2
152
1
305