Sharp AL-1552 Operation Manual page 81

Digital multifunctional system
Hide thumbs Also See for AL-1552:
Table of Contents

Advertisement

Personal Protective Equipment
Respiratory Protection
Hand Protection
Eye Protection
Skin Protection
Other Protective Equipment
9.PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Physical State : Solid
Ph
Boiling / Melting Point
Softening Point(°C)
Flash Point(°C)
lgnition Point(°C )
Explosion Properties
Density(g/cm³)
Solubility in Water
10.STABILITY AND REACTIVITY
Stability
Hazardous Reactions
Conditions to Avoid
Materials to Avoid
Hazardous Decomposition Products
Further Information
11.TOXICOLOGICAL INFORMATION
Acute Toxicity
Ingestion(oral)
Dermal
Inhalation
Eye irritation
Skin irritation
Skin sensitizer
Mutagenicity
Carcinogenicity
MATERIAL SAFETY DATA SHEET
: Not required under intended use.
: Not required under intended use.
: Not required under intended use.
: Not required under intended use.
: Use of a dust mask and goggles are recommended when handling a large
quantity of toner or during long term exposure, as with any non-toxic dust.
Form : Powder
: Not applicable
: Not applicable
: No data
: Not applicable
: No data
: No data
: 1.1 (bulk density : 0.34)
: Negligible
: Stable
: Dust explosion, like most finely divided organic powders.
: Electric discharge, throwing into fire.
: Oxidizing Materials
: CO, CO
: None
: LD
> 2000mg/kg (Rats)
50
: LD
> 2000mg/kg (Rats)
50
: No Data
: Not an irritant
: Not an irritant
: No sensitization
: Negative (Ames Test)
: In 1996 the IARC reevaluated carbon black as a Group 2B carcinogen (possible human
carcinogen). This classification is given to chemicals for which there is inadequate human
evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity. The
classification is based upon the development of lung tumors in rats receiving chronic inhalation
exposures to free carbon black at levels that induce particle overload of the lung. Studies
performed in animal models other than rats did not show any association between carbon black
and lung tumors. Moreover, a two-year cancer bioassay using a typical toner preparation
containing carbon black demonstrated no association between toner exposure and tumor
development in rats.
Color : Black
and NO
2
X
Page: 3/4
Date Revised: Jul. 31. 2002
Date Issued : Jun. 1. 1998
MSDS No. F-00831
Odor : odorless