NordicTrack T23.0 User Manual page 31

Treadmill
Hide thumbs Also See for T23.0:
Table of Contents

Advertisement

Locate the Reed Switch (52), and locate the
Magnet (50) on the left side of the Pulley (49). Turn
the Pulley until the Magnet is aligned with the Reed
Switch. Make sure that the gap between the
Magnet and the Reed Switch is about 1/8 in. (3
mm). If necessary, loosen the #8 x 3/4" Tek Screw
(14), move the Reed Switch slightly, and then
retighten the Screw. Reattach the Motor Hood (not
shown) and run the treadmill for a few minutes to
check for a correct speed reading.
Top
View
52
14
1/8 in.
SYMPTOM: The incline of the treadmill does not
change correctly
a. Hold down the Stop button and the Speed increase
button, insert the key into the console, and then
release the Stop button and the Speed increase
button. Press the Stop button and then press the
Incline increase or decrease button. The tread-
mill will automatically rise to the maximum incline
level and then return to the minimum level. This will
recalibrate the incline system. If the incline system
does not begin calibrating, press the Stop but-
ton again, and then press the Incline increase or
decrease button again. When the incline system is
calibrated, remove the key from the console.
SYMPTOM: The walking belt slows when walked on
a. If an extension cord is needed, use only a 3-con-
ductor, 14-gauge (1 mm
than 5 ft. (1.5 m).
49
50
) cord that is no longer
2
b. If the walking belt is overtightened, treadmill per-
formance may decrease and the walking belt may
become damaged. Remove the key and UNPLUG
THE POWER CORD. Using the hex key, turn both
idler roller screws counterclockwise, 1/4 of a turn.
When the walking belt is properly tightened, you
should be able to lift each edge of the walking belt
2 to 3 in. (5 to 7 cm) off the walking platform. Be
careful to keep the walking belt centered. Then,
plug in the power cord, insert the key, and run the
treadmill for a few minutes. Repeat until the walk-
ing belt is properly tightened.
b
2–3 in.
Idler Roller Screws
c. Your treadmill features a walking belt coated with
high-performance lubricant. IMPORTANT: Never
apply silicone spray or other substances to
the walking belt or the walking platform unless
instructed to do so by an authorized service
representative. Such substances may deterio-
rate the walking belt and cause excessive wear.
If you suspect that the walking belt needs more
lubricant, see the front cover of this manual.
d. If the walking belt still slows when walked on, see
the front cover of this manual.
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netl18711.0

Table of Contents