General Condition:
1 .Electrical connection: Steady state voltage: 0.9-1.1
of nominal voltage.
Frequency: 0.99-1.01 of nominal frequency
continuously; 0.98-1.02 short time
The mains connection must have maximum16A fuse.
Electrical supply which has protection devices of
under-voltage, over-voltage, over-current as well as
a residual current device (RCD) which maximum
residual current rated at 0.03A.
2 . Altitude are not exceeding 1000m,
Maximum ambient air temperature is +40 ˚ ,
minimum ambient air temperature is not less than
storage and transportion temperature
O
+5
C,
range is -25 ˚C~+55 ˚C.
The relative humidity does not exceed 50% at a
maximum temperature of +40 ˚C, higher relative
humidity may be permitted at lower temperature
(e. g. 90%@ 20 ˚C).
Floor Load
This machine represents a moderately large weight
load in a small footprint. Most commercial shop floors
will be adequate for the weight of the machine. Some
floors may require additional support. Contact an
architect or structural engineer if you have any question
about the ability of your floor to handle the weight.
To ensure sufficient upright stability of the machine
it should be bolted to floor. For this purpose 4 holes
are provided in the machine's bracket of workstand.
Working Clearances
Working clearances can be thought of as the distances
between machines and obstacles that allow safe
operation of every machine without limitation. Consider
existing and anticipated machine needs, size of
material to be processed through each machine, and
space for auxiliary stands and/or work tables. Also
consider the relative position of each machine to one
another for efficient material handling. Be sure to allow
yourself sufficient room to safely run your machines in
any foreseeable operation.
Consider existing and anticipated needs, size of
material to be processed through each machine, and
space for auxiliary stands, work tables or other
machinery when establishing a location for your saw.
See above figure for the maximum working clearances
of the Sliding Panel Saw.
Lighting and Outlets
Lighting should be bright enough to eliminate shadow
and prevent eye strain. Electrical circuits should be
dedicated or large enough to handle combined motor
amp loads. Outlets should be located near each
machine so power or extension cords are not
obstructing high-traffic areas. Be sure to observe local
electrical codes for proper installation of new lighting,
outlets, or circuits.
Dust Collector
As a rule, this machine must be vacuumed during use. A
time relayed socket is available as an accessory. In
addition, the vacuum performance must be sufficient to
achieve the required negative pressures and a
maximum air speed of 20m/sec at the connector.
Read the manual before assembly and operation.
Become familiar with the machine and it's
operation before beginning any work. Serious
personal injury may result if safety or operational
information is not understood or followed.