Heatilator RAVE4013I-C Owner's Manual page 30

Gas fireplace
Table of Contents

Advertisement

Figure 7.11
30
Top Vent - Vertical Termination
Venting with 2 elbows
V
Minimum
1
90° Elbow
1 ft,
152 mm
2 ft.
457 mm
3 ft.
914 mm
4 ft.
1.1 m
* No specifi c restrictions on this value EXCEPT V
V
2
H
1
Heatilator • RAVE4013I-C • 2293-900 Rev. i • 4/14
RAVE4013I-C
H Maximum
2 ft.
610 mm
3 ft.
914 mm
5 ft.
1.5 m
7 ft.
2.1 m
15 ft.
4.6 m
H MAX. =15 ft. (4.6 m)
V
+ V
+ H MAX. = 40 ft. (12.2 m)
1
2
+ V
1
2
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).
V
1
V
V
+ V
2
1
2
*
*
*
*
*
+ H cannot exceed 40 ft. (12.2 m)