1. Top Vent - Horizontal Termination - (continued)
V
Minimum
1
90° Elbow
1 ft.
305 mm
2 ft.
610 mm
3 ft.
914 mm
V
*No specifi c restrictions on this value EXCEPT V
Figure 7.6
Top Vent - Horizontal Termination
Venting with 3 elbows
RAVE4013I-C
H
+ H
Maximum
1
2
6 ft.
1.8 m
10 ft.
3.0 m
12 ft.
3.7 m
14 ft.
4.3 m
H
+ H
MAX. =14 ft. (4.3 m)
1
2
+ V
+ H
+ H
MAX. = 40 ft. (12.2 m)
1
2
1
2
+ V
+ H cannot exceed 40 ft. (12.2 m)
1
2
H
2
Heatilator • RAVE4013I-C • 2293-900 Rev. i • 4/14
V
V
+ V
Minimum
2
1
2
*
*
*
*
*
*
*
*
CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps are not approved for use with pro-
pane (LP) fuel. May lead to elevated glass temper-
ature that may cause tempered glass breakage.
V
2
H
1
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).