1. Top Vent - Horizontal Termination - (continued)
V Minimum
3 ft.
914 mm
H
+ H
+ H
1
2
3
V
MAX. = 7 ft (2.1 m)
1
V
1
Figure 7.7
28
Top Vent - Horizontal Termination
Venting with 3 elbows
H
+ H
+ H
MAXIMUM
1
2
3
RAVE4013I-C (NG ONLY)
15 ft.
4.6 m
MAX. = 15 ft. (4.6 m)
INSTALLED
HORIZONTALLY
H
1
Heatilator • RAVE4013I-C • 2293-900 Rev. i • 4/14
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).
CAUTION: The SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps are not approved for use with pro-
pane (LP) fuel. May lead to elevated glass temper-
ature that may cause tempered glass breakage.