Shutdown - Graco 309550Y Instructions - Parts Manual

Plural component, impingement mix air purge spray gun
Table of Contents

Advertisement

Shutdown

Shutdown
For overnight shutdown:
1.
Follow Pressure Relief Procedure, page 15.
2.
Leave air turned on and gun detriggered.
Grease gun daily to prevent 2 component curing
and keep fluid passages clean. Purge air carries
grease mist through air chamber (AC), impinge-
ment ports (IP), and out mix chamber nozzle (N),
coating all surfaces. Use Graco 117773 Grease,
see page 43.
KEY
Purge Air
Fluid
Cleanoff Air
Grease
TI3547a
G
19
14
3.
4.
5.
AC
IP
N
TI3546a
Remove grease fitting cap. Using grease gun (Y),
dispense grease into fitting (G) until grease mist
sprays from mix chamber nozzle (N). Do not
over-grease; use 2 shots maximum. Do not spray
grease mist on sprayed material.
Y
G
N
Replace grease cap.
Round and Flat pattern guns only: Turn off air
valve (W).
Spatter pattern gun only: Shut down main air sup-
ply.
W
TI2415A
309550Y

Advertisement