2-4. LOCATION (Continued)
The models BCF-110 and BCR-110 require a 1 inch (25 mm) drain line.
2-5. REFRIGERANT
INFORMATION

2-6. COMPRESSOR SIZE

2-4
BCF/BCM-110
Refrigerant Type
BCF-65
R404A
BCF-24
R404A
BCF-110/
R404A
BCM-110
BCF-24
BCF-65
BCF/BCM-110
Model BCF-24/65/110, BCM-110
Amount of Refrig.
3.3 lbs (1.5 kg)
2.4 lbs (1.1 kg)
3.3 lbs (1.5 kg)
.75 Horsepower
1.5 Horsepower
2.5 Horsepower
Design Pressure
High
Low
345 psig
190psig
(23.8 bar) (13.1 bar)
335 psig
195 psig
(23.1 bar) (13.4 bar)
425 psig
174 psig
(29.3 bar) (12.0 bar)
1105