Fireplace Installation

New Wall Construction

1. Mark the desired location on
the floor and store the fire-
place in a safe, dry and dust
free location.
2. Use studs to frame an open-
ing of 31 ¾ in. (807 mm) wide
x 22 ¾ in. (578 mm) high x
9 ½ in. (241 mm) deep.
Option #1 - The power cord can
be lead from behind the trim
and along the wall to an outlet
near the fireplace.
Option #2 - A new outlet can be
installed inside the new frame
construction. Plug the unit di-
rectly into a 15 A, 120 V outlet.
!
NOTE 1: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not es-
sential in all cases. A dedi-
cated circuit will be required
if, after installation, the circuit
breaker trips or fuse blows
on a regular basis when the
heater is operating. Additional
appliances on the same circuit
may exceed the current rating
of the circuit breaker.
Option #3 - Hardwire
1. Wire a dedicated, properly
fused circuit with 120 Volt,
8
15 Amp rating. Allow up to
8 ft. (2.4 m) of service cable
for connecting power supply
to junction box on fireplace
when installing after finishing
wall.
CAUTION: Use two conduc-
tor, non-metallic sheath cable
with ground wire (3 wires total)
for the incoming power supply on
fireplace inserts. Use appropriate
wire to meet local and national
electrical codes for rated power
Figure 2
Figure 3