Page 1
For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, please visit www.dimplex.com 7207500100R09...
CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. W ARNINg: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
Welcome & Congratulations Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex, the world leader in electric fireplaces. Please carefully read and save these instructions. CAUTION: read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty.
Do not insert or allow foreign ⑤ Do not operate any unit with objects to enter any ventilation a damaged cord or plug, or if the or exhaust opening as this may CAUTION rIsK oF ELECTrIC sHoCK Do noT oPEn no usEr-sErVICEABLE PArTs InsIDE www.dimplex.com...
IMPORTANT INSTRUCTIONS cause an electric shock or fire, or If you must use an extension damage to the heater. cord, the cord must be no. 14 AWG minimum size and rated no ⑪ To prevent a possible fire, do less than 1875 Watts. not block air intake or exhaust ⑮...
Page 6
FCC CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. www.dimplex.com...
(see Figure 1 for recommended installation clearances.) Fireplace Installation Dimplex mantel, the fireplace Install the fireplace assembly must be installed in an into the mantel (refer to mantel enclosure with the following assembly instructions).
Page 9
Fireplace Installation Plug the unit into a 15 Amp/120 Figure 1 Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 Watts. " 654 mm CAUTION: Clearance for " 298 mm air circulation beneath the fireplace insert is provided by "...
The temperature cutoff switch are turned on simultaneously. can be reset by unplugging the When the manual control unit, waiting five (5) minutes and is in the Flame & Heat plugging the unit back position the heater does not www.dimplex.com...
Operation CAUTION: If you need to Figure 3 continuously reset the heater, unplug the unit and call Dimplex north America Limited at 1-888-346-7539. Please have your model and serial Batteries number ready when calling. Remote Control Child Lock The remote control has a range of approximately 50 feet (15.25...
Page 12
Purifire™ is set at low speed. Press the Q or the R buttons to D. Flame Speed Control change between low and high While the fireplace is running, speeds. Press the g button to press the N button to increase the www.dimplex.com...
Page 13
Operation Figure 4 - Remote Control Functions A. room Temperature B. set Temperature C. Light Dimmer Control D. Flame speed Control E. sleep Timer F. Purifire™ G. Purifire™ on/off H. Flame & Heat on/off I. Temperature Down J. Temperature up K.
Page 14
Child Press the button on the Lock is bypassed. When the remote. backlight is off the Child Lock is re-activated. Your remote will now have a different frequency Figure 5 communicating with the fireplace. Locked unlocked Child Lock Tab www.dimplex.com...
Maintenance bulbs above that illuminate the log WARNINg: Disconnect exterior. power before attempting any maintenance or cleaning to Helpful Hints reduce the risk of fire, electric It is a good idea to replace all shock or damage to persons. light bulbs at one time if they are close to the end of their rated life.
Page 16
Assembly’s LED wire harness Upper Light Bulb Requirements from unit. Quantity of two (2) clear unscrew bulbs counter chandelier or candelabra bulbs clockwise. with an E-12 (small) socket base, Insert new bulbs and screw in 15 Watt rating. clockwise. www.dimplex.com...
Page 17
Maintenance Do not exceed 15 Watts per corners of the fireplace. bulb. unscrew bulbs counter To access the upper light bulb clockwise. area: Insert new bulbs and screw in slide fireplace out of mantel. clockwise. Remove four (4) Phillips re-install upper Light Bracket. screws from right side of trim slide front glass back into (Figure 6).
To prevent scratching, do not use abrasive cleaners or spray liquids on the glass surface. Fireplace Surface Cleaning use a cloth dampened with warm water only to clean painted surfaces of the electric fireplace. Do not use abrasive cleaners. www.dimplex.com...
(a) a repair or replacement warranty on following model of your newly purchased defective products or parts, including Dimplex electric fireplace DF3015 and in-home services, for the first 1 year to newly purchased Dimplex fireplace following the date of first purchase; and (b) surrounds (mantels) and trims.
Page 20
(ii) a proof of purchase of the product. the purchaser is solely responsible for providing clear access to all What Dimplex will do in the event of a serviceable parts of the product. defect •...
Page 21
AGEnTs HAVE BEEn the first anniversary of the date of ADVIsED oF THE PossIBILITY oF first purchase, Dimplex will in its sole suCH LossEs, CosTs or DAmAGEs, discretion either repair or replace such or IF suCH LossEs, CosTs, or defective surrounds (mantels) and DAmAGEs ArE ForEsEEABLE.