6.4

Replacing a 2.5-inch HDD/SSD module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see
HDD/SSD module" on page
Under no circumstances should you remove an HDD/SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
V
Only applicable for removing non-defective HDD/SSD modules:
Ê Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD/SSD module that is
not defective.
6.4.1

Required tools

Preliminary and concluding steps: tool-less
Main steps: tool-less
BX920 S4