Viessmann VITODENS 100-W Installation And Service Instructions Manual page 17

Wall-mounted, gas-fired condensing boiler heating input 37 to 118 mbh 10.8 to 34.5 kw
Hide thumbs Also See for VITODENS 100-W:
Table of Contents

Advertisement

Wall Mounting
(continued)
Mounting bracket installation (continued)
a
Fig. 9
Installation of mounting bracket
16" / 406 mm
Fig. 10
Installation of mounting bracket on wood studs
16" / 406 mm
Fig. 11
Installation of mounting bracket on metal studs
a = 16" / 406 mm
2x
3/16"
2x
5/8"
Installation of mounting bracket on
wood and metal studs
To mount the Vitodens 100-W boiler
on wood or metal studs, install
mounting bracket on wall as shown on
previous page. Refer to drawings on
the left and below for more detailed
installation information.
Install mounting bracket on wood studs
3
as per illustration. Drill
/
16
to insert mounting bolts. Ensure that
holes are located in the center of each
wood stud.
Install mounting bracket on metal studs
5
as per illustration. Drill
/
" pilot holes
8
to insert mounting bolts. Ensure that
holes are located in the center of each
metal stud. Secure mounting bracket
with bolts to metal studs as shown.
" pilot holes
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vitodens 100-w wb1b series

Table of Contents