Honeywell ADEMCO VISTA-10P Installation And Setup Manual page 19

Hide thumbs Also See for ADEMCO VISTA-10P:
Table of Contents

Advertisement

Using the AVS System with AVS Module and AVST Remote Stations
The AVS system provides audio alarm verification via the phone line.
To use the AVS with this control, the AVS must be set for non-addressable mode by setting the module to
address 31.
Refer to the instructions included with the AVS system for installation procedures.
The following is a summary.
Mounting the AVS Base Unit
As shipped, the AVS Base unit board comes pre-
mounted on its mounting bracket, which is designed to
mount inside the control cabinet.
Refer to the diagram at right.
a. Position the mounting plate/PC board assembly in
the bottom of the control's cabinet.
b. Slide the mounting plate to the right so that the
plate's left-hand tang slides under the cabinet's tie-
wrap loop.
c. Secure the assembly to the cabinet using the two
self-tapping screws provided.
BATTERY NOTE: When using a 7AH battery, mount the battery vertically on the bottom left-hand side of
the cabinet, with the terminals facing down and right (negative terminal closest to the PC board bracket).
Programming the Control for AVS
2. Enable the AVS operation by setting data field *91 for AAV operation.
3. Use *80 Menu mode to program the connected AAV trigger output (output 17) and, if used, CO trigger
output (output 18) as follows:
Output 17 for AAV trigger:
zone type (ZT) = 60 (AAV), action = 1 (close for 2 seconds), device = 17.
Output 18 for CO trigger (requires two output functions):
to activate:
zone type (ZT) = 14 (CO), action = 2 (stay closed), device = 18.
to deactivate: zone type (ZT) = 22 (disarm, code + OFF), action = 0 (off), device = 18.
4. Use *56 Menu mode to program the appropriate voice session monitoring zone as follows (zone 6
recommended): zone type = 81; hardwire type = 2 (NO, normally open)
Setting Base Unit DIP Switch Options
Use the 4-position DIP switch to select various installation options. The functions of the 4-position switches
are described below. Switches in the up position are ON (ON is marked on the switch housing). Switches in
the down position are OFF.
Use the 5-position DIP switch to set the module to non-addressable mode (all switches OFF).
Refer to the diagram below and set the 4-position DIP switch as required.
PROGRAM MODE
CALLBACK MODE
PANEL TRIGGER MODE
NORMAL MODE
DIP SETTING NOTES:
Callback Mode:
Central Station calls panel to initiate voice session.
Panel Trigger Mode: Voice session starts automatically following delivery of alarm report.
Program Mode:
Set switch to ON to program the callback code.
Normal Mode:
Set switch to OFF when programming of callback code is complete.
Trigger Inputs:
Trigger Inputs: Positive trigger is normally low and triggers when signal goes high. Negative
trigger is normally high and triggers when signal goes low.
CO INPUT: ON = POSITIVE TRIGGER (NORM LOW TRIGGERS ON HIGH)
BELL INPUT: ON = POSITIVE TRIGGER (NORM LOW TRIGGERS ON HIGH)
ON
1
2
3
4
BELL INPUT: OFF = NEGATIVE TRIGGER (NORM HIGH TRIGGERS ON LOW)
CO INPUT: OFF = NEGATIVE TRIGGER (NORM HIGH TRIGGERS ON LOW)
DIP SWITCH
SYSTEM
BATTERY
ON
ON
4
5
1
2
3
1
2
3
4
TANG
BENEATH
MOUNTING
PLATE
SLIDE ASSEMBLY TO RIGHT UNTIL
TANG SLIPS UNDER CABINET LOOP
SECURE
WITH TWO (2)
SELF-TAP SCREWS
(SUPPLIED)
CABINET
TIE-WRAP
LOOP
AVS-003-V0
AVS-APX-015-V0
2-13