Error, Maintenance And Warranty - Rinnai E75CN User's Information Manual

High efficiency condensing gas boiler
Table of Contents

Advertisement

Available languages

Available languages

Error, maintenance and warranty

i
NOTICE
i
NOTICE
i
NOTICE
i
NOTICE
9
8
14
If a fault is detected the boiler will be blocked.
This will be reflected, by an alternate display of
Good, with an
a number code.
You can try to reset the boiler by pressing the
Reset key once. If the problem remains please
contact your installer and inform them about
the fault and give them the number code.
If you discover any leaks from the boiler
contact your installer.
We advise you to obtain a service contract
with your installer for regular maintance and
adjustment to keep your boiler safe and in
good condition.
The casing of the boiler consists of plastic
parts which can be cleaned with a normal non
abrasive cleaning agent.
Periodic cleaning of the condensate collection and
disposal system must be carried out.
Before putting the boiler into operation after
periodic cleaning fill the condensate trap with
1.27 cups / 300 ml of water.
Step 1: Condensate trap
- first remove the screw (7);
7
- pull the condensation cup (8) downwards, out
of the condensate tray
Check this for impurities. If there are no impurities
it is not necessary to clean the condensate cup;
- check the O-ring (9) of the cup and replace it if
necessary;
- clean the parts by flushing it with clean water;
- grease the O-ring again with acid free O-ring
grease to make fitting easier;
E
of Error or a BL of Blocking and

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents