6) Remove the strap connecting the spout to the chute assembly, then remove the spout.
Spout
Rubber O-Ring
Nylon O-Ring
(if applicable)
Extruding Head
Evaporator
Assembly
7) Pour the cleaning solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to overflow into the drain pan.
Note: If there is excess scale on the extruding head, fill the evaporator assembly and
reservoir as described above, then use a clamp on the reservoir hose between
the reservoir and evaporator assembly to block flow. Pour additional cleaning
fluid over the extruding head until the evaporator assembly is completely full.
8) Replace the spout and strap in their correct positions.
9) Allow the icemaker to sit for about 10 minutes before operation. If you placed a clamp
on the reservoir hose in step 7, remove it before operation.
10) In bad or severe water conditions, clean the float switch assembly as described below.
See Fig. 15. Otherwise, continue to step 12.
a. Remove the float switch assembly from the reservoir cover.
b. Wipe down the float switch assembly with the cleaning solution.
c. Rinse the float switch assembly thoroughly with clean water.
d. Replace the float switch assembly in its correct position.
Packing
Actuator
Strap
Baffle
Reservoir
Chute
Float Switch Assembly
Reservoir Cover