Hoshizaki FD-1001MLH(-C) Service Manual page 103

Modular flaker
Hide thumbs Also See for FD-1001MLH(-C):
Table of Contents

Advertisement

3. On water-cooled model only, first remove the water from the water-cooled
condenser:
1) Make sure the power supply is off, then remove the front and right side panels.
2) Close the condenser water supply line shut-off valve. If connected to a closed loop
system, also close the condenser return line shut-off valve.
3) Open the condenser water supply line drain valve. If connected to a closed loop
system, also open the condenser return line drain valve.
4) Attach a compressed air or carbon dioxide supply to the condenser water supply line
drain valve.
5) Open the water regulating valve by using a screwdriver to pry up on the spring retainer
underneath the spring. While holding the valve open, blow out the condenser using the
compressed air or carbon dioxide supply until water stops coming out.
6) Close the drain valve(s).
7) Replace the right side panel and front panel in their correct positions.
103