Pin Assignments For The Coil Cable - Metrologic MS6720 Installation And User Manual

Hand-held laser scanner
Hide thumbs Also See for MS6720:
Table of Contents

Advertisement

A
C
PPENDIX

Pin Assignments for the Coil Cable

The MS6720 scanners are terminated to a 10 position shielded modular
connector. All coil cables (
terminated the same. The difference between versions is the end of the
cable going into the scanner. This connector plugs into different "J"
positions on various computer/interface boards. Since each
computer/interface board is different, the output signals are different.
Version "9" (OCIA)
Pin
Function
1
Power/Signal Ground
2
RDATA
3
RDATA Return
4
Clock In
5
Clock In Return
6
Clock Out
7
Clock Out Return
8
No Connection
9
+5 VDC Power to Scanner
10
OCIA Shield Ground
Version "14" (232)
PinFunction
1
Power/Signal Ground
2
RS-232 Transmit Output
3
RS-232 Receive Input
4
RTS Output
5
CTS Input
6
DTR Input
7
DSR Output
8
No Connection
9
+5 VDC Power to Scanner
10
Shield Ground
44-44780) for the MS6720 scanner are
MLPN
Version "11" (46XX)
Pin
1
2
3
4
5
6
7
8
9
10
Version "15" (LTPN)
Pin
10
Function
Power/Signal Ground
RS-232 Transmit Output
RS-232 Receive Input
RTS Output
CTS Input
IBM 46XX Transmit
IBM 46XX Receive
No Connection
+5 VDC Power to Scanner
Shield Ground
Function
1
Power/Signal Ground
2
RS-232 Transmit Output
3
RS-232 Receive Input
4
RTS Output
5
CTS Input
6
Light Pen Source +5V
7
Light Pen Data
8
No Connection
9
+5 VDC Power to Scanner
Shield Ground