5D) Three Wire Flexible Conduit Con-
nection
14. Properly secure flexible conduit at knockout on angle and at supply side junc-
tion box. The wiring is now complete.
Figure 14:
Note: DO NOT plug in range at this time.
The Four Wire Connection is preferred, but where local codes and ordinances
permit grounding through neutral and/or conversion to four wire is impractical, unit
may be connected to the power supply via a three wire connection.
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the terminal block.
3. Remove the top nut, star washer, and round washer from each post.
Note: DO NOT remove last round washer, last nut or internal wire leads.
4. Place one terminal lug (packaged with this manual) on each post. Replace the
star washer and round washer and secure with 20 inch pounds of torque.
5. Strip 3/8 (9.53 mm) inches of insulation from the end of each wire.
green
ground
screw
red wire
green ground wire
Completed Four Wire Flexible Conduit Connection
black wire
white wire
Terminal Block
Figure 15:
Wire Stripping
Figure 16: