DANGER
Some laser products contain an embedded Class 3A or Class 3B laser
diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view
directly with optical instruments, and avoid direct exposure to the beam.
Class 1 Laser Product
Laser Klasse 1
Laser Klass 1
Luokan 1 Laserlaite
`
Appareil A Laser de Classe 1
7. Touch the static-protective package that contains the new optical drive to any
unpainted metal surface on the server; then, remove the optical drive from the
package and place it on a static-protective surface.
8. Attach the drive retention clip that you removed from the previous drive to the
side of the new drive.
9. Align the drive in the drive bay and slide the drive into the CD/DVD drive
bay until the drive clicks into place.
If you have other devices to install or remove, do so now. Otherwise, go to
"Completing the installation" on page 112.

Installing a PCI riser-card assembly

To install a PCI riser-card assembly, complete the following steps:
1. Read the safety information that begins on page "Safety" on page v and the
"Installation guidelines" on page 44.
2. Turn off the server (see "Turning off the server" on page 24) and all attached
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
3. Remove the top cover (see "Removing the server top cover" on page 46).
4. Install the adapter in the PCI riser-card assembly (see "Installing an adapter"
on page 70).
5. Align the PCI riser-card assembly with the PCI slot connector on the system
board and align nailheads with the slots on the chassis; then, press down firmly
until the riser-card assembly is seated correctly in the connector on the system
board.
Chapter 2. Installing optional devices