3

Conversion to propane

3
Conversion to propane
Read the instructions before conversion for your safety.
RISK TO LIFE
due to not observing the attached
conversion instructions.
WARNING!
If you wish to convert the boiler for
operation with propane, the conversion
from natural gas to propane must be
carried out first as specified by the
attached conversion instructions.
The following instructions must be followed for
conversion of the boiler to propane:
1. If the boiler has been operating, close the gas valve.
Otherwise continue with step 3.
2. Disconnect heating system from the power supply
and set the thermostat to the lowest setting.
3. Remove safety screws from the left and right side
panels, then lift the front panel of the boiler and pull
it forward.
4. Turn gas valve ON/OFF button clockwise to OFF
position. Do not use force.
RISK TO LIFE
from explosion of flammable gases.
Wait five (5) minutes until all gas
WARNING!
residues have dissipated. Check
whether there is any smell of gas,
including at floor level. If there is a gas
odor: STOP! Follow instructions in
section "B" of the safety instructions on
Page 9. If there is no sign of a gas odor,
continue with the next step.
4
We reserve the right to make any changes due to technical modifications.
Instructions for conversion kit for Logano G334 X gas-fired boiler • Issue 09/2005
Fig. 1
Removing front panel of boiler
1 Screws
2 Boiler front panel
Fig. 2
Gas valve
2
1
1