Gas Conversion; Gas Conversion Kits; Gas Pipe Conversion Kit; Gas Pipe - Buderus Logano plus GB102 Instructions Manual

Gas conversion kit
Hide thumbs Also See for Logano plus GB102:
Table of Contents

Advertisement

Gas Conversion

2
2
Gas Conversion
NOTICE: COMBUSTION TESTING
▶ Combustion testing must be carried out by
a competent person. Testing must not be
attempted unless the person carrying out
the combustion check is equipped with a
calibrated Combustion Analyser and is
competent in its use
NOTICE: CO/CO
▶ If the joint between the Air/Gas manifold
and heat exchanger is disturbed the
sealing gasket must be replaced
▶ After completing the service of the
appliance, the CO/CO
the limits shown in the relevant
Installation, Commissioning and Servicing
instructions
CAUTION: Appliance siting
▶ This appliance must not be installed into a
room or internal space below ground level
when it is intended for use with LPG
(Propane - G31). This does not preclude
the installation into a room or space that is
in a basement on one side of the building
but is open to ground level on the opposite
side
2.1

Gas Conversion kits

To convert to LPG, a Gas Conversion kit is required.
The kit comprises:
Gas pipe assembly

– Gas pipe

– O ring
– Dust shield
– Securing nut
Heat Control Module (HCM)
HCM tether
Labels to confirm the new gas type
Table 1, page 5, lists the Gas Conversion kit part numbers.
4
CHECKS
2
must be checked to
2
2.2

Gas pipe conversion kit

CAUTION: Mains supplies
▶ Turn off the gas supply and isolate the
electrical mains supply before starting any
work on the appliance and observe all
relevant safety precautions
Refer to the Installation, Commissioning and Servicing
instructions and remove the boiler front panel and combustion
chamber cover and put the control panel in the service
position.
2.2.1 Gas pipe
The gas pipe is supplied already assembled for ease of
installation.
3
4
Fig. 1
Gas pipe assembly
[1] Gas pipe
[2] Dust shield
[3] O ring
[4] Securing nut
[4] Heat Control Module (HCM)
Logano plus GB102GB102S– 6 720 812 906 (2014/09)
1
2
5
6720812906-01.1Wo

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logano plus gb102s

Table of Contents