Replacing Headlight; Replacing Belt - Hoover Vacuum Systems Owner's Manual

Hoover company central vacuum systems accessories owner's manual
Table of Contents

Advertisement

W i n d Tunnel™ power
n o z z l e
The belt
The belt in your power nozzle drives the
a g i t a t o r. It has been designed specifically
for use in this nozzle and is important for
e ffective operation.
What to buy
Use only a genuine HOOVER B e l t N o .
40201180 when a belt replacement is nec-
e s s a ry.
4 - 1 1
Return nozzle to original position and lift
off hood.
4 - 1 4
F
If belt is not broken but is stretched or
cut, pull it off the motor pulley (F).
8
When to replace
The belt should be checked from time to
time to be sure it is in good condition. To
check, remove the hood (see following
section). Replace the belt if it is stre t c h e d ,
cut, or bro k e n .
How to re p l a c e
With CORDED hose,disconnect hose
p ower cord from electrical outlet. W i t h
CORDLESS hose,disconnect end of
hose from electrified inlet va l v e. T h e n
disconnect power nozzle from ex t e n s i o n
w a n d s .
4 - 1 2
E
Remove brush roll cover (E) by remov-
ing the 3 Phillips head screws.
4 - 1 5
G
Lift up end of agitator brush roll. Remove
old belt from agitator pulley (G) and
replace with new belt. Lettering on belt
must be visible.
4 - 1 0
To remove hood, turn nozzle over and
unscrew the 4 recessed Phillips head
screws.
Note: Do not remove the 3 screws in
the triangle formation as these hold
the motor in place.
4 - 1 3
E
Lift off brush roll cover (E).
4 - 1 6
H
Stretch belt back and attach to motor
pulley.
Hold opposite end of agitator brush roll in
place. Push belt end forw a rd, ro t a t i n g
end plate (H) until it slides into place.
Tu rn agitator, making sure it rotates fre e l y.

Hide quick links: