Chapter 3. Master Reset And Program Re- Set Master Resetting; Master Resetting; Program Resetting (Initializa- Tion) - Sharp XE-A40S Service Manual

Hide thumbs Also See for XE-A40S:
Table of Contents

Advertisement

CHAPTER 3.
XE-A40S
MASTER RESET AND PROGRAM RESET

[1] MASTER RESETTING

Master resetting clears the entire memory and resumes default values.
Master resetting can be accomplished by using the following proce-
dure:
Procedure A:
1)
Unplug the AC cord from the wall outlet.
2)
Set the mode switch to the PGM position.
3)
While holding down both the JOURNAL FEED key
and [CL] key, plugin the AC cord to the wall outlet.
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically performed
after the power has been restored.
(This is because if power failure occurs with no battery attached to the
machine, all the memory will be lost and the machine does not work
properly after power recovery; this requires the master reset opera-
tion.)
[2] PROGRAM RESETTING (INITIALIZA-
TION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Procedure:
1)
Unplug the AC cord from the wall outlet.
2)
Set the mode switch to the PGM position.
3)
While holding down both JOURNAL FEED key
and RECEIPT FEED key, plugin the AC cord to
the wall outlet.
NOTE: In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically per-
formed after the power has been restored.