Troubleshooting - Central Pneumatic 68029 Set Up And Operating Instructions Manual

20 gauge wide crown air stapler
Table of Contents

Advertisement

fastener by probing the openings in the
magazine.
3.
Pull out the jammed fastener and the
remainder of the fastener strip that is
still in the magazine. Dispose of the
remaining fastener strip; it may be bent
or damaged in some other way.

Troubleshooting

Problem
Tool will not fire.
1. Restricted air flow.
2. Trigger is locked.
Insufficient
1. Not enough air pressure.
fastener depth.
2. Incorrect lubrication or not
3. Mechanism contaminated.
Fasteners drive
Too much air pressure.
too deeply.
Tool cycles
1. Jammed fastener.
without firing
fastener.
2. Tool empty.
3. Incorrect fasteners used.
4. Magazine dirty or not
5. Insufficient air flow.
Frequent
Incorrect fastener type.
jamming.
Severe air
1. Cross-threaded housing
leakage.
(Slight air leakage
is normal,
2. Loose housing.
especially on
older tools.)
3. Damaged valve or housing.
4. Dirty, worn or damaged valve.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect air supply before service.
SKU 68029
Possible Causes
enough lubrication.
lubricated properly.
components.
For technical questions, please call 1‑800‑444‑3353.
4.
If you are unable to clear the fastener
jam using the method prescribed above,
the tool should be taken to a qualified
service technician for proper servicing.
Likely Solutions
1. Open in-line shut-off valve.
2. Disengage Trigger Safety Lock.
1. Check for loose connections and make sure that
air supply is providing enough air pressure (PSI) to
the tool's air inlet. Do not exceed maximum air
pressure of 120 PSI.
2. Lubricate using air tool oil and grease according to
directions.
3. Have qualified technician clean and lubricate
mechanism. Install in-line filter in air supply as
stated in Initial Set Up: Air Supply.
Reduce air supply pressure (PSI).
1. Clear jammed fastener according to Clearing Jams
instructions.
2. Fill with correct fasteners.
3. Empty, then fill with correct fasteners.
4. Clean and lubricate magazine and pusher rod.
5. Check for loose connections and make sure that
air supply is providing enough air flow (CFM) and
pressure (PSI) to the tool's air inlet. Do not exceed
maximum air pressure of 120 PSI.
Confirm fastener diameter, type, length, angle, and
collation type. Correct as needed.
1. Check for incorrect alignment and uneven gaps. If
cross-threaded, disassemble and replace damaged
parts before use.
2. Tighten housing assembly. If housing cannot tighten
properly, internal parts may be misaligned.
3. Replace damaged components.
4. Clean or replace valve assembly.
Page 13