Troubleshooting

Problem
Tool will not
1. Low or no air pressure.
operate.
2. Corroded Piston Assembly
3. Damaged seals or O-rings.
Insufficient
1. Not enough air pressure.
fastener depth.
2. Incorrect lubrication or
3. Mechanism contaminated.
Fasteners drive
Too much air pressure.
too deeply.
Tool cycles
Insufficient air flow.
without firing nail.
Severe air
1. Cross-threaded housing
leakage.
(Slight air leakage
is normal,
2. Loose housing.
especially on
older tools.)
3. Damaged valve or housing.
4. Dirty, worn or damaged valve.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect air supply before service.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Record Product's Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only,
and are not available individually as replacement parts.
Page 10
Possible Causes
(12).
not enough lubrication.
components.
For technical questions, please call 1-800-444-3353.
Likely Solutions
1. Check that compressor is working properly. Check air
regulator. Check air lines for leaking or blockage.
2. Spray light weight penetrating oil into the
Air Inlet (17). If tool still won't operate,
take to a qualified service technician for repair.
3. Take tool to a qualified service technician for repair.
1. Check for loose connections and make sure that air
supply is providing enough air pressure (PSI) to the
tool's air inlet. Do not exceed maximum air pressure.
2. Lubricate using air tool oil and grease
according to directions.
3. Have qualified technician clean and lubricate
mechanism. Install in-line filter in air supply
as stated in Initial Set Up: Air Supply.
Reduce air supply pressure (PSI).
Check for loose connections and make sure that air supply
is providing enough air flow (CFM) and pressure (PSI) to the
tool's air inlet. Do not exceed maximum air pressure.
1. Check for incorrect alignment and uneven gaps.
If cross-threaded, disassemble and
replace damaged parts before use.
2. Tighten housing assembly. If housing cannot tighten
properly, internal parts may be misaligned.
3. Replace damaged components.
4. Clean or replace valve assembly.