Rap 11 Serial Interface Problem - Oki Microline 520 Service Handbook

Oki microline 520/521 service handbook
Hide thumbs Also See for Microline 520:
Table of Contents

Advertisement

%RAP 11 Serial Interface Problem

RAP 11 Serial Interface Problem
START.
Are you using a cable with the proper number of pins?
No Change the interface cable.
Has the problem been resolved?
Yes End of procedure
No Go to A
Yes Is the ALARM LED blinking?
Yes Refer to Section 4.6 of the Service Handbook.
Has the problem been resolved?
Yes End of procedure
No Go to A
No Go to A
A
Check the serial interface parameters for the RS232C (in the Printer Menu): baud rate, word length,
parity, protocol, busy signal and parity.
Has the problem been resolved?
Yes End of procedure
No Go to B
B
Check the voltages on the main control board.
Is 10 VAC being supplied to the main control board?
Yes Replace the RS232C board.
Has the problem been resolved?
Yes End of procedure.
No Replace the main control board.
Has the problem been resolved?
Yes End of procedure.
No Contact Technical Support.
No Replace the power supply unit.
Has the problem been resolved?
Yes End of procedure.
No Replace the RS232C board.
Are + 8 vdc / - 8 vdc present on the main control board? (Refer to Appendix A of this Service
Handbook).
Yes Replace the RS232C board.
Has the problem been resolved?
Yes End of procedure.
No Contact Technical Support.
No Replace the main control board.
Has the problem been resolved?
Yes End of procedure.
No Contact Technical Support.
ML520/521 ( 96-02-04 )

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microline 521

Table of Contents