USER PROGRAM
The conditions of factory setting can be changed according to the use conditions.
1. Functions which can be set with the user program
Function
When a certain time is passed after completion of copying, this function returns to the
Auto clear.
initial state automatically. The time to reach the initial state can be set in the range of
30 sec to 120 sec by the unit of 30 sec. This function can be disabled.
When the copier is left unused with the power ON, the power consumption is
automatically reduced to about 40Wh/H ( Note).
The time to start this function can be set in the range of 30 sec to 90 sec by the unit
Pre-heat.
of 30 sec. This function cannot be disabled.
When this function is operated, the pre-heat lamp on the operation panel lights up.
To return to the initial state, press any key on the operation panel. (When the COPY
button is pressed, a copy is made after returning to the initial state.)
When the copier is left unused with the power ON, the power consumption is
automatically reduced to about 18Wh/H ( Note). The time to start this function can be
Auto shut off
set in the range of 2 min to 120 min.
passing time.
When this function is operated, all the lamps except for the pre-heat lamp on the
operation panel turn off.
To return to the initial state, press the COPY button.
After completion of copying with the automatic document feeder (SPF), when documents
Stream feeding.
are set while the SPF indicator is blinking (for about 5 sec), the documents are
automatically fed.
Auto shut off setting
Used to set or cancel this function.
Note: The power consumption values in pre-heat and auto shut off may be varied depending on the use conditions.
2. Change the setting.
Example: Changing the time to operate the auto shut off func-
tion (Change from 60 sec to 90 sec)
1) Press the right and the left exposure adjustment keys
simultaneously to start setting.
Keep pressing the keys for five sec.
Display lamps (
,
-" is displayed on the copy quantity display.
2) Select the function code with the 10-digit key (copy
quantity set key).
The number of the selected function blinks on the digit of 10
on the copy quantity display.
For auto clear, select "1."
For setting, refer to the following function codes.
Function
Function
Set code
name
name
0 (Cancel)
1 (30 sec)
2 (60 sec)
Auto clear
Pre-heat
3 (90 sec)
4 (120 sec)
: Factory setting
The number of the selected set code blinks on the digit of 1
of the copy quantity display.
[Cancel] When a wrong number of the function code is set,
press the clear key and perform the procedure again
from 2.
5) Press the COPY button.
The number blinking on the digit of 1 of the copy quantity
display is lighted up. This means the setting is completed.
,
blink simultaneously and "-
Function
Set code
name
0 (30 sec)
1 (60 sec)
Auto shut
2 (90 sec)
off
Contents
Function name
Auto clear
Pre-heat
Auto shut off passing time
Stream feeding
Auto shut off setting
[Cancel] If a wrong code is entered, press the clear key and
enter the correct function code.
3) Press the COPY button.
The number blinking on the digit of 10 of the coyp quantity
display is lighted.
The number of the current set code blinks on the digit of 1.
4) Select the setting code with 1-digit key (copy quantity
set key).
To set to 90 sec, select "3."
For setting, refer to the following set codes.
Function
Set code
name
0 (2 min)
1 (5 min)
Stream
2 (15 min)
feeding
3 (30 min)
4 (60 min)
5 (120 min)
[Note] To set another function, press the clear key after com-
pletion of this operation and perform the procedure
from 2.
6) Press either one of exposure adjustment keys
(
or
) to complete the setting.
Display lamps (
tity display returns to the normal state.
8-1
Factory setting
60 sec
90 sec
5 min
Function code
1
2
3
4
5
Function
Set code
Set code
name
0 (Cancel)
0 (Cancel)
1 (Setting)
1 (Setting)
Auto shut
off setting
,
,
) go off and the copy quan-
Set
Set