Set is dead and makes hiccupping sound
"Main Power Supply" is available. Hiccupping stops when L5561is de-soldered,
meaning that problem is in the "Main Power Supply" line. No output voltages at
LOT, no horizontal deflection. Reason: line transistor 7460 is defective.