The Blinking Led Procedure - Philips 7629 Service Manual

Color television
Table of Contents

Advertisement

How To Read The Error Buffer
You can read the error buffer in 3 ways:
On screen via the SDAM (if you have a picture). Examples:
ERROR: 0 00 0 0 : No errors detected
§
ERROR: 6 0 0 0 0 : Error code 6 is the last and only detected error
§
ERROR: 9 6 0 0 0 : Error code 6 was detected first and error code 9 is the
§
last detected (newest) error
Via (when you have no picture). See "The Blinking LED Procedure"
Via ComPair.
How To Clear The Error Buffer
The error code buffer is cleared in the following cases:
By using the CLEAR command in the SDAM menu:
To enter SDAM, press the following key sequence on the remote control
§
transmitter:
0-6-2-5-9-6-MENU
§
Do not allow the display to time out between entries while keying the sequence.
§
Make sure the menu item CLEAR is highlighted. Use the MENU
§
UP/DOWN buttons, if necessary.
Press the MENU RIGHT button to clear the error buffer. The text on the
§
right side of the "CLEAR" line will change from "CLEAR?" to "CLEARED"
If the contents of the error buffer have not changed for 50 hours, the error buffer
resets automatically.
Note:
If SDAM is exited by disconnecting the AC power from the television set, the error buffer
is not reset.