Protections - Philips 7629 Service Manual

Color television
Table of Contents

Advertisement

Error Codes
In case of non-intermittent faults, write down the errors present in the error buffer and
clear the error buffer before you begin the repair.
This ensures that old error codes are no longer present.
If possible, check the entire contents of the error buffer. In some situations an error
code is only the result of another error and not the actual cause of the problem (for
example, a fault in the protection detection circuitry can also lead to a protection).
Table: Error Code Table
ERROR Device
0
Not applicable
1
Not applicable
2
Not applicable
3
TDA8359/TDA9302
4
MSP34X5/TDA9853
5
TDA95XX
Error
Check
description
item
No Error
X-Ray
2465,
Protection
7460
7460,
7461,
Horizontal
7462,
Protection
7463,
6467
7861,
Vertical
VloAux
Protection
+13v
MAP I2C
7831,
identification
7861
error
7200,
POR 3.3V /
7560,
8V Protection
7480
Diagram
A2
A2
A2, A3
A9 or
A11
A1, A2.
A5, A6,
A7

Hide quick links: