Installer System Test; System Status - Honeywell FOCUSPRO TH5110D Installation Manual

Focusprotm th5000 series non-programmable digital thermostat
Hide thumbs Also See for FOCUSPRO TH5110D:
Table of Contents

Advertisement

Available languages

Available languages

Installer setup
Setup function
Shaded areas below apply only to TH5220D.
9
Stage 1 compressor
cycle rate (CPH)
10
Stage 2 compressor
cycle rate (CPH)
12
Manual/Auto
changeover
14
Temperature
display
15
Compressor
protection
26
Auxiliary heat control
27
Heat temperature
range stops
28
Cool temperature
range stops

Installer system test

To begin, press and hold the
buttons until the display changes
System test
Shaded areas below apply only to TH5220D.
10
Heating system
20
Emergency heating
system
30
Cooling system
40
Fan system
CAUTION: Compressor protection is bypassed during testing. To prevent equipment
!
damage, avoid cycling the compressor quickly
Settings & options (factory default in bold)
3
Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
3
Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
0
Manual changeover (Heat/Cool/Off)
1
Auto changeover (Heat/Cool/Auto/Off)
2
Auto changeover only (Auto)
0
Fahrenheit
1
Celsius
5
Five-minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]
0
Comfort **See page 8
1
Economy
90
Max. heat temperature setting is 90 °F (32 °C)
[Other options: 40 °F to 89 °F (4.5 °C to 31.5 °C)]
50
Min. cool temperature setting is 50 °F (10 °C)
[Other options: 51 °F to 99 °F (10.5 °C to 37 °C)]
and
s
t

System status

0
Heat and fan turn off.
1
Stage 1 heat turns on. Fan turns on if Setup Function 1 is set to 1
or 5 OR Setup Function 3 is set to 1 **See page 6
2
Stage 2 heat turns on
0
Heat and fan turn off
1
Heat and fan turn on
2
Stage 2 heat turns on (auxiliary heat)
0
Compressor and fan turn off
1
Compressor and fan turn on
2
Stage 2 compressor turns on
0
Fan turns off
1
Fan turns on

FocusPRO
Test number
10
Press
/
to turn system on/off.
s
t
Press NEXT to advance to next test.
Press DONE to terminate system test.
TH5110 / TH50
TM
System status
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Focuspro th5220d

Table of Contents