Honeywell CHRONOTHERM T8600D Product Data page 15

Deluxe programmable thermostats
Hide thumbs Also See for CHRONOTHERM T8600D:
Table of Contents

Advertisement

T8600D, T8601D AND T8602D CHRONOTHERM
NOTE: The display changes from the setpoint to the
room temperature after approximately 3
seconds.
5. Press Run Program to cancel the Hold and to return to
the program.
Changing Temperature Setting Until a
Designated Day and Period
1. Press Hold Temp twice.
Time
Set Program
Run
Set Current
Wake
Leave
Return
Hold Temp
Program
Day/Time
Heat/Cool
Hold Temp
Day
System
Settings
Daylight
Copy
Time
2. Press Time
or Time
days is displayed (1 to 255 days). (Example: 18 = Hold
will override the daily programs for 18 days)
Time
Time
Set Program
Set Current
Run
Leave
Wake
Return
Program
Day/Time
Heat/Cool
Hold Temp
Day
System
Settings
Daylight
Copy
Time
3. Press Wake, Leave, Return or Sleep to select the
period the program will start. (Example: Return =
thermostat will stop the Hold at the Return period start
time)
Time
Set Program
Run
Set Current
Wake
Leave
Return
Return
Day/Time
Program
Heat/Cool
Hold Temp
Day
System
Settings
Daylight
Copy
Time
4. Press increase
or decrease
temperature setting, if desired. (Example: Heat 54° =
heating equipment will operate when the room
temperature is below 54°F)
Time
Set Program
Run
Set Current
Wake
Leave
Return
Day/Time
Program
Heat/Cool
Hold Temp
Day
System
Settings
Daylight
Copy
Time
NOTE: When the System is set for Auto (select
models), both heat and cool settings are
needed. If the System is set for Heat, only the
Heat setpoint is needed or if Cool is selected,
only the Cool setpoint is needed.
5. Press Heat/Cool Settings to change between heat and
cool settings.
6. Press increase
or decrease
temperature setting, if desired. (Example: Cool 84° =
cooling equipment will operate when the room
temperature is above 84°F)
®
Setting
Hold for
Heat
Sleep
Wake
Fan
M10337
until the desired number of
Setting
Hold for
Heat
Sleep
Wake
Fan
M10338
Setting
Hold for
Heat
Sleep
Return
Fan
M10339
key to adjust the
Setting
Hold for
Heat
Sleep
Return
Fan
M10340
key to adjust the
IV DELUXE PROGRAMMABLE THERMOSTATS
NOTE: In this example, the thermostat uses the Hold setting
for eighteen days and returns to the daily programs
at the Return period start time. The temperature
settings are heating 54°F and cooling 84°F. Only the
heating temperature is used because the System is
set for Heat. The thermostat will use both the heating
and cooling temperature settings when the System
is set to Auto (select models).
IMPORTANT
If the Hold needs to be canceled before the
designated time, press Run Program to return to the
program.
Setting System and Fan
The system default setting is Heat and the fan default setting
is Auto. Use the System and Fan keys to change the settings.
See Fig. 12. The fan settings can be set for each program
period individually. The system selection is for all the program
periods.
System settings control the thermostat operation as follows:
Heat: The thermostat controls the heating.
Off: Both the heating and cooling are off.
Cool: The thermostat controls the cooling.
Auto: The thermostat automatically changes between
heating and cooling operation, depending on the indoor
temperature.
Fan settings control the system fan as follows:
On: Fan operates continuously.
Auto: Fan operates with equipment.
Time
Run
Set Current
Program
Day/Time
Hold Temp
Day
Daylight
Copy
Time
Fig. 12. Thermostat System and Fan key locations.
Setting Temporary Fan Operation
If your thermostat has a Fan key and this feature, press Fan
until the desired fan operation is selected. This fan setting will
be in effect until the next regularly scheduled period starts.
15
Set Program
Leave
Wake
Return
Sleep
Heat/Cool
System
Fan
Settings
M15042
System
Fan
68-0164—1