Honeywell CHRONOTHERM T8600D Product Data page 9

Deluxe programmable thermostats
Hide thumbs Also See for CHRONOTHERM T8600D:
Table of Contents

Advertisement

T8600D, T8601D AND T8602D CHRONOTHERM
Installer Setup
Number (Press
Time
change)
Select
Not used
31 and 32
Minimum off time
33
for the
compressor
Temperature
34
range stops in
heating
Temperature
35
range stops in
cooling
Not used
36
Temperature
37
display
adjustment
a
Number 2 must be set to 1 to extend fan operation.
IMPORTANT
Review the settings to confirm that they match the
system. Press Run Program to exit the Installer
Setup. The thermostat has saved the Installer Setup
changes and initiated a reset in order to operate with
these new settings. Be sure to set the current day
and time immediately.
Setting Current Day and Time
1. Press Set Current Day/Time.
NOTE: On initial power up or after an extended power
loss, 1:00 pm flashes on the display until a key
is pressed.
Time
Set Program
Set Current
Run
Set Current
Wake
Leave
Return
Program
Day/Time
Day/Time
Heat/Cool
Hold Temp
Day
System
Settings
Daylight
Copy
Time
®
Table 6. Thermostat Installer Setup Options (continued).
Factory-Setting
key to
Display
Description
5
5 minute minimum off
time for the
compressor
90
Highest setpoint
heating can be set to
45
Lowest setpoint
cooling can be set to
0
No difference in
displayed temperature
and actual room
temperature
Set Day/Time
PM
Mon
Sleep
Fan
M10312
IV DELUXE PROGRAMMABLE THERMOSTATS
(Press
Display
0 thru 4
Minimum number of minutes (0
thru 5) the compressor will be
off between calls for the
compressor
40 to 89
Temperature range (1°F
increments) heating setpoint
can be set to
46 to 99
Temperature range (1°F
increments) cooling setpoint
can be set to
3 thru -3
1—Display adjusts to 1°F
2—Display adjusts to 2°F
3—Display adjusts to 3°F
-1—Display adjusts to 1°F lower
-2—Display adjusts to 2°F lower
-3—Display adjusts to 3°F lower
2. Press Day until the current day is displayed.
NOTE: Sun=Sunday, Mon=Monday, Tue=Tuesday,
Wed=Wednesday, Thu=Thursday, Fri=Friday,
Sat=Saturday.
Run
Set Current
Program
Day/Time
Day
Hold Temp
Day
Daylight
Time
3. Press Time
displayed.
NOTE: Tapping the Set Current Day/Time will change
the time in one hour increments.
Time
Run
Set Current
Program
Day/Time
Hold Temp
Day
Daylight
Time
9
Other Choices
or
key to change)
Description
higher than actual room
temperature
higher than actual room
temperature
higher than actual room
temperature
than actual room temperature
than actual room temperature
than actual room temperature
Set Day/Time
PM
Time
Set Program
Tue
Wake
Leave
Return
Sleep
Heat/Cool
System
Fan
Settings
Copy
or Time
until the current time is
Set Day/Time
AM
Time
Set Program
Tue
Wake
Leave
Return
Sleep
Heat/Cool
System
Fan
Settings
Copy
Actual
Setting
M10313
M10314
68-0164—1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents