Line Lock Phase Adjustment Potentiometer - Honeywell HCC334L User Manual

L-series color camera ntsc/pal
Hide thumbs Also See for HCC334L:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Line Lock Phase Adjustment
Potentiometer
When the camera is in Line lock mode, it is possible to
adjust the point on the AC cycle at which the camera
triggers. This feature allows for synchronization of cameras
that are connected to different phases.
The V-PHASE adjustment potentiometer allows the line lock
phase trigger point to be adjusted by 270°. Rotating the
potentiometer clockwise advances the trigger point and
turning it counterclockwise retards the trigger point. The
factory default setting is the zero crossing point. If all
cameras in a system are on the same phase then no line
lock phase adjustment should be made.
Rev 3
8
G-113077-002
01/07

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcc334lxHcc484lHcc484lxHcc335lxHcc485lx

Table of Contents