Honda GENERATOR EB3800X Owner's Manual page 26

Honda power equipment portable generator user manual
Hide thumbs Also See for GENERATOR EB3800X:
Table of Contents

Advertisement

Voltage Selector Switch
The power available to each receptacle depends on the position of the
voltage selector switch.
Switch Position
120V ONLY
120V/240V
120V ONLY Position
When the voltage selector switch is in the 120V ONLY position, you
do not need to spread the load over the receptacles. You must,
however, make sure the load on any receptacle does not exceed its
available power shown in the preceding table and the total load does
not exceed 27.5 amps.
120V/240V Position
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 13.8 amps.
Set of
Receptacles
1
+ +
3
4B
2
4A
24
Receptacle
1
2
3
4A
4B
1
2
3
4A-4B
Total Current
Available
13.8A
13.8A
Available Power
27.5A at 120V
20A at 120V
20A at 120V
20A at 120V
None
13.8A at 120V
13.8A at 120V
13.8A at 120V
13.8A at 240V
Power Producing
Circuit
1
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eb5000xEb6500xEb6500x

Table of Contents