Disassembly And Reassembly Procedure - Robin EC05-2 Service Manual

Table of Contents

Advertisement

6-3 DISASSEMBLY
and
REASSEMBLY PROCEDURE
6-3-3 FUEL TANK
and FUEL TANK BRACKET
'
1) Disconnect fuel pipe between strainer and carburetor at carburetor side.
2 )
Remove mounting bolts, and detach fuel tank from cylinder head or cylinder.
3)
For Model ECl OV
'
Unscrew
6
x
M8
bolts, then remove fuel tank from blower housing.
CAUTION: REPLACE FUEL PIPE ONCE A
YEAR IN ORDER TO PREVENT FROM THE OCCURANCE OF
DANGER CAUSED
BY
THE FUEL LEAKAGE.
6-3-2 AIR CLEANER
"Model
EC05-2D & 6,07-2D &
B,
10D &
B,
17D &
B,
25-2D & DS
1)
Remove air cleaner cover and element.
2) Unscrew two or three bolts which clamped
air
cleaner base plate to carburetor and remove base plate.
Model ECIOV
1) Remove
cover and take out outer element and inner element.
2 ) Loosen three bolts which clamped base plate to carburetor, and remove base plate.
In reassembly:
Wash element based
on following procedure before reassembly;
'Model
EC05-2D
&B,
07-2D &
6,
1 O D & 6,170 &
B,
and
25-2D & DS
After washed element with gasoline, soak
it into the mixed o i l of 2
-
4 kerosene and 1 engine
oil,
then reassemble it after
drip the oil off.
"
Model EClOV
After washed outer and inner elements with gasoline, soak them into the mixed
o i l of 2
-
4 kerosene and 1 engine oil.
6-3-3 CARBURETOR
1)
Remove governor rod and rod spring from carburetor..
2 ) Remove carburetor from cylinder block.
In reassembly:
Refer t o section "8. GOVERNOR" and section "9. CARBURETOR".
6-3-4 GOVERNOR LEVER
1) Remove governor lever from governor shaft.
2)
Remove governor spring from control lever.
3) Control lever and stop plate can be removed by loosing wing-nut or bolt but do not disassemble unless it necessary.
NOTE: When control lever device are disassembled, tentatively assemble them together with governor lever.
In reassembly:
Refer t o section "8. GOVERNOR". Assembly shall be made securely including rotation adjustment.
6-3-5
MUFFLER
Unscrew nuts and remove it from cylinder.
6-3-6 BLOWER
HOUSING
1 )
Disconnect stop button wires from Connector.
2) Unscrew bolts and remove blower housing from crankcase.
\
f
\
-
24
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec07-2Ec10Ec17Ec25-2