Standby Power; Connections To A Building's Electrical System; System Ground - Honda Companion 00X31-Z07-7010 Owner's Manual

Honda power equipment generator owner's manual
Table of Contents

Advertisement

STANDBY POWER

Connections to a Building's Electrical System

Connections for standby power to a building's electrical system must
be made by a qualified electrician. The connection must isolate the
generator power from utility power, and must comply with all
applicable laws and electrical codes.
In some areas, generators are required by law to be registered with
local utility companies. Check local regulations for proper registration
and use procedures.

System Ground

Honda portable generators have a system ground that connects the
generator frame components to the ground terminals in the AC output
receptacles. The system ground is not connected to the AC neutral
wire. If the generator is tested with a receptacle tester, it will not show
the same ground circuit condition as for a home receptacle.
Improper connections to a building's
electrical system can allow current
from the generator to backfeed into
the utility lines.
Such backfeed may electrocute
utility company workers or others
who contact the lines during a
power outage, and the generator
may explode, burn, or cause fires
when utility power is restored.
Consult the utility company or a
qualified electrician prior to making
any power connections.
OPERATION
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Companion 31z07701Companion eu2000i

Table of Contents