Weil-McLain Ultra Manual page 69

Gas-fired water boilers – series 3
Table of Contents

Advertisement

-
gas
fired water boiler
U-Control operation and setup
Figure 87
U-Control diagnostic information (see Figure 85, page 64 for location in menu sequence), continued
Menu/Item
Units
Manual Reset
yes or none
Auto Reset
yes or none
Inputs
menu
Outputs
menu
Temperatures
menu
Lockout History 3
Time & Date
text
Status
text
Manual Reset
yes or none
Auto Reset
yes or none
Inputs
menu
Outputs
menu
Temperatures
menu
Software Versions
Display
#.## format
Main Micro
#.## format
Second Micro
#.## format
Manual Test Mode
Status
text
Target
°F
Modulation
°F
System Supply
°F
System Return
°F
Boiler Out
°F
Boiler In
°F
Flame Signal
no units
Blower Signal
% of rate
Blower Tach
rpm
Force Rate
Manual Reset
Maintenance Info
Name
text
Phone
text
Model
text
CP Number
text
Installed
text
Last Date
text
Next Date
text
Interval Settings
months
Reset Reminder
menu
Set Time and Date
Year
text
Month
text
Day
text
Hour
text
Minute
text
Part number 550-100-066/0608
— Boiler Manual
Low
High
Default
Value
Value
data
data
menu
menu
menu
data
data
data
data
menu
menu
menu
data
data
data
data
data
data
data
data
data
data
data
data
data
Low, Med, High, or Auto
Auto
blank
blank
blank
blank
blank
data
data
6
24
12
menu
2008
1
1
12
0
(continued)
Comment
Choose this to view the details of manual reset lockouts
Choose this to view the details of auto reset lockouts
Choose this to view the status of the Boiler Inputs at the time of the error
Choose this to view the status of the Boiler Outputs at the time of the error
Choose this to view the Boiler Temperatures at the time of the error
Choose this to view the third most recent error recorded
Displays time and date that lockout occurred
Displays what the status of the boiler at the time of the error
Choose this to view the details of manual reset lockouts
Choose this to view the details of auto reset lockouts
Choose this to view the status of the Boiler Inputs at the time of the error
Choose this to view the status of the Boiler Outputs at the time of the error
Choose this to view the Boiler Temperatures at the time of the error
Software version of the microprocessor on the display circuit board
Software version of the main microprocessor on the control circuit board
Software version of the second microprocessor on the control circuit board
Current operating status of the boiler. Prepurge, Ignition, Name of the system Type being
satisfied, post purge, Warm Weather Shutdown, Trouble
Calculated target temperature based on outdoor temp or the max setpoint if no ODR
Temperature of the sensor the boiler is using to base its modulation
Temperature of the remote mounted system water supply sensor
Temperature of the remote mounted system water return sensor
Temperature of the outlet sensor on the boiler heat exchanger
Temperature of the inlet sensor on the boiler heat exchanger
Number indicating the presence and quality of the flame used to shutdown boiler
Control's output to the blower
Blower's feedback to the control
Used to manually force a rate during a call for heat. Choose auto for normal operation.
Reset selected condition
Contractor name to appear in maintenance reminders and during lockouts
Contractor phone number
Displays the boiler model selected in the boiler setup
Enter the CP# of the boiler
Enter the date the boiler was installed
Date automatically entered when Reset Reminder is choose by contractor
Date automatically calculated when Reset Reminder is selected by contractor
Contractor selects maintenance reminder frequency based on service history
Contractor selects this to update Last maintenance Date and Next Date. Homeowner uses
this to ignore the reminder and update only the Next Date.
Set year (homeowner or contractor)
Set month (homeowner or contractor)
Set day (homeowner or contractor)
Set hour (homeowner or contractor)
Set minute (homeowner or contractor)