Viewfinder screen (Factory default setting)
** FUNCTION 1/2 **
TEST OUT
: ENC
DETAIL
: ON
APERTURE
: ON
SKIN TONE DTL
: OFF
MATRIX
: OFF (for NTSC)
: ON (for PAL)
GAMMA
: ON
CHROMA
: ON
TEST SAW
: OFF
CROSS COLOR FLT : OFF
(for NTSC only)
DNW-7/90/90WS
Description
........... Selects the ENC, R, G or B signal of the video signal output from the TEST
OUT connector.
n
When the R-G/B-G SEL item on the OP MODE page is set to ON, the R-G and
B-G items are added enabling to select R-G and B-G.
........... Sets whether to add the detail signal for resolution improvement to the video
signal.
n
The level adjustment for this item is performed on the "LEVEL 1" page.
........... Sets the aperture correction to ON or OFF.
........... Sets whether to activate the skin tone detail circuit.
n
The level adjustment for this item is performed on the "LEVEL 2" page.
........... Sets whether to activate the linear matrix circuit.
The highly color saturation can be obtained when this item is set to ON.
n
The level adjustment for this item is performed on the "LEVEL 8" page.
........... Sets whether to implement the gamma correction so that the overall character-
istic of signals from the camera to monitor display is "GAMMA = 1".
n
The level adjustment for this item is performed on the "LEVEL 3" and "LEVEL
6" pages.
........... Sets whether to add the chroma signal.
n
The level adjustment for this item is performed on the "LEVEL 4" page.
........... Sets whether to close the lens forcibly and add the TEST SAW waveform to the
video signal circuit.
This signal is used for the video signal system adjustment.
........... Sets whether to reduce the cross color of a video signal. The cross color is
reduced when this item is set to ON.