Fujitsu D3049 Technical Manual

Fujitsu D3049 Technical Manual

System board for primergy tx140 s1 / tx120 s3

Advertisement

Technical Manual - English
System Board D3049
for PRIMERGY TX140 S1 / TX120 S3
Technical Manual
Edition May 2012

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D3049

  • Page 1 Technical Manual - English System Board D3049 for PRIMERGY TX140 S1 / TX120 S3 Technical Manual Edition May 2012...
  • Page 2 – The contents of this manual may be revised without prior notice. – Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. – No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.
  • Page 3 Before reading this manual For your safety This manual contains important information for safely and correctly using this product. Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product.
  • Page 4 Please consult the sales staff of Fujitsu if intending to use this product for high safety use. Measures against momentary voltage drop This product may be affected by a momentary voltage drop in the power supply caused by lightning.
  • Page 5 Only for the Japanese market: Although described in this manual, some sections do not apply to the Japanese market. These options and routines include: – USB Flash Module (UFM) – CSS (Customer Self Service) Technical Manual TX140 S1 / TX120 S3...
  • Page 6 Technical Manual TX140 S1 / TX120 S3...
  • Page 7: Table Of Contents

    Contents Introduction ......9 Notational conventions ....10 Important information .
  • Page 8 Contents Technical Manual TX140 S1 / TX120 S3...
  • Page 9: Introduction

    DVDs (see Installation DVD of ServerView Suite - ServerView Software Products). You will find further information about the BIOS setup in the "D3049 BIOS Setup Utility for PRIMERGY TX140 S1 / TX120 S3" manual.
  • Page 10: Notational Conventions

    Introduction Model lines for TX120 S3 There are two model lines for the TX120 S3 server: – TX120 S3 – TX120 S3p For the European market: You can identify the model line by the model name "TX120 S3p" printed on the identification rating plate and on the ID card. For the Japanese market: "TX120 S3p"...
  • Page 11: Important Information

    Important information In this chapter you will find essential information regarding safety when working with your server. CAUTION! With the system board installed you must open the system to access the system board. How to access the system board of your system is described in the appropriate Upgrade and Maintenance Manual.
  • Page 12 Important information CAUTION! Components can become very hot during operation. Ensure you do ● not touch components when making extensions to the system board. There is a danger of burns! Transmission lines to peripheral devices must be adequately ● shielded. Ethernet cabling has to comply with EN 50173 and EN 50174-1/2 ●...
  • Page 13 Important information Modules with Electrostatic-Sensitive Devices Modules with electrostatic-sensitive devices are identified by the following sticker: Figure 1: ESD label When you handle components fitted with ESDs, you must always observe the following points: Switch off the system and remove the power plugs from the power outlets ●...
  • Page 14: Ce Certificate Of Conformity

    Important information Notes about boards During installation/deinstallation of the board, observe the specific ● instructions described in the Upgrade and Maintenance Manual for the respective server. Shut down the server and disconnect the power plug, before you make ● modifications on an installed board. To prevent damage to the board, the components and conductors on it, ●...
  • Page 15: Environmental Protection

    Important information Environmental protection Environmentally-friendly product design and development This product has been designed in accordance with the Fujitsu standard for "environmentally friendly product design and development". This means that key factors such as durability, selection and labeling of materials, emissions, packaging, ease of dismantling and recycling have been taken into account.
  • Page 16 Details regarding the return and recycling of devices and consumables within Europe can also be found in the "Returning used devices" manual, via your local Fujitsu branch or from our recycling center in Paderborn: Fujitsu Technology Solutions Recycling Center D-33106 Paderborn Tel.
  • Page 17: Features

    Model lines for TX140 S1 There are two model lines for the TX140 S1 server: – TX140 S1 – TX140 S1p The following table provides an overview of the different features: TX140 S1 TX140 S1p System board D3049-Axx D3049-Bxx ® ® ® ® Processors...
  • Page 18 Model lines for TX120 S3 There are two model lines for the TX120 S3 server: – TX120 S3 – TX120 S3p The following table provides an overview of the different features: TX120 S3 TX120 S3p System board D3049-Axx D3049-Bxx ® ® ® ® Processors...
  • Page 19 Features TX120 S3 TX120 S3p PCI slots 1x PCI 3.0 (32 Bit / 33MHz) 1x PCI 3.0 (32 Bit / 33MHz) 1x PCIe x16 Gen 2 1x PCIe x16 Gen 3 1x PCIe x4 Gen 2 1x PCIe x4 Gen 2 (mechanical x8) (mechanical x8) 1x PCIe x1 Gen 2...
  • Page 20: Overview

    Features Overview Processors – one processor socket LGA1155 ® ® ® – one Intel Xeon Pentium , or Core i3 processor – CPUs with up to 95 W TDP (FMB 2011D) are supported Main memory – up to 4 slots for main memory –...
  • Page 21 Features Internal connectors – 1x USB CCR / DAT connector (only one of both can be used at the same time) – 1x Mini SAS/SATA connector (4 ports) – 2x SATA connectors – 1x power supply connector 16 pin (12V and 12V auxiliary) –...
  • Page 22 Features Power management – ACPI (states S0, S4, S5) – 3.3 V auxiliary power on the PCI / PCI Express slots – on/off/sleep/wake by power button – on/off by software – wake on by RTC, external serial connector (COM1), LAN, PCI, PCI Express controller and iRMC S3 –...
  • Page 23 Features USB Flash Module (option) The system board can be equipped with an USB Flash Module (UFM) by the manufacturer or by an add-on kit. The module is used by VMware. TPM (option) The system board can be equipped with a TPM (Trusted Platform Module) by the manufacturer or by an add-on kit.
  • Page 24: Main Memory

    Features Main memory You will find the descriptions how to install memory modules in the Upgrade and Maintenance Manual of your server. DIMM1B DIMM2B DIMM1A COM1 DIMM2A SATA POWER Jumper FRONT LAN FAN2 SYS Management LAN/ USB 9/10 Figure 2: Slots of the main memory 3.2.1 Module population –...
  • Page 25: Modes Of Operation

    Features Configuration per Max. speed DIMM-2 DIMM-1 channel DDR3-1333/1600 empty SR/DR DDR3-1333/1600 SR/DR SR/DR 3.2.1.2 Modes of operation Dual-channel symmetric mode Dual-channel asymmetric mode M em ory s iz e M em ory s iz e A M em ory s iz e B channe l channe l Figure 3: Dual-channel symmetric and asymmetric mode...
  • Page 26: Pci Slots

    Features PCI slots Standard LAN/ FAN1 SYS USB 5/6 SATA MLC1 Slot 4 PCIe x16 Indicate HDD ACTIVITY Slot 3 PCIe x4 USB1AUX iRMC 3 Cougar SATA6 Point PCH Slot 2 PCIe x1 USB1 Slot 1 PCI 32 Bit / 33 MHz Intrusion Battery Figure 4: PCI slots...
  • Page 27: Screen Resolution

    Features Screen resolution Depending on the operating system used the screen resolutions in the following table refer to the graphic controller on the system board. The graphic controller is integrated in the iRMC S3 (integrated Remote Management Controller). Screen resolution Maximum refresh Max.
  • Page 28 Features Fan control The fans are regulated according to temperature. Sensor monitoring The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware.
  • Page 29: Connectors And Indicators

    Slot 3 PCIe x4 USB1AUX iRMC 3 Cougar SATA6 Point PCH Slot 2 PCIe x1 USB1 Slot 1 PCI 32 Bit / 33 MHz Intrusion Battery Figure 5: Internal connectors of the system board D3049 Technical Manual TX140 S1 / TX120 S3...
  • Page 30 Features No. Print Description POWER1 Power supply connector PC2009 Power supply connector Reset Connector for RESET switch Frontpanel Front panel /USB connector SATA POWER Power supply connector FRONT LAN Connector for LAN on the front side FAN2 SYS Connector for system fan 2 FAN1 CPU Connector for CPU fan SATA MLC...
  • Page 31 Features DIMM1B DIMM2B DIMM1A COM1 DIMM2A SATA POWER Jumper FRONT LAN FAN2 SYS Management LAN/ USB 9/10 Shared LAN/ USB 7/8 FAN1 CPU Standard LAN/ FAN1 SYS USB 5/6 SATA MLC1 Slot 4 PCIe x16 Indicate HDD ACTIVITY Slot 3 PCIe x4 USB1AUX iRMC 3 Cougar...
  • Page 32 Features The LEDs have the following meaning: Indicator Meaning A - GEL no error (non CSS component) (Global Error orange on indicates a prefailure (non CSS LED) component) orange flashing indicates a failure of a non CSS component. Reasons for a failure may be: –...
  • Page 33: Connector Panel

    (blue); (description see preceding section) The management LAN connector can be set in the BIOS. You will find further information in the "D3049 BIOS Setup Utility for PRIMERGY TX140 S1 / TX120 S3" manual. The serial connector COM1 can be used as default interface or to communicate with the iRMC S3.
  • Page 34 Features LAN connectors The system board is equipped with a Gigabit Ethernet Controller of the type ® Intel 82574L and 82579LM. The LAN controller supports transmission rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s. The LAN controller (only for Shared LAN) also supports WOL functionality by means of Magic Packet™.
  • Page 35: Settings

    Features Settings 3.7.1 Jumper DIMM1B Default DIMM2B DIMM1A DIMM2A SATA POWER RCVR Jumper FRONT LAN FAN2 SYS PWD SKIP Figure 9: Jumper Setting Description Default Password delete disabled and recovery BIOS disabled. RCVR Recovery BIOS enabled. When the recovery BIOS is applied on a system board, the password set by customers disappears from system board.
  • Page 36 Features Technical Manual TX140 S1 / TX120 S3...

Table of Contents