Technical Data

Type
Category
see rating label
This appliance is designed to operate with Butane at nominal pressure: 28 ÷ 30 mbar. For
a regular gas combustion the required air quantity is: 8,4 m
-
ALWAYS use heater in accordance with instructions. Read the instructions book carefully
and keep it in a safe place.
-
This appliance requires a rubber tube and a pressure regulator in accordance with the
law in force. If not supplied check with your gas supplier.
-
Use ONLY in a well ventilated area.
-
This appliance MUST NOT be used in basements, high rise flats, bathrooms or
bedrooms and in rooms having volume less than 15m
-
This appliance emits the combustion residues in the room in which is used.
-
DO NOT place clothes or other materials on the heater, as apart from the danger of fire
their presence could affect the efficient working of the appliance (fig. 1).
-
DO NOT move heater from room to room when it is lit (fig. 2).
-
DO NOT position heater alongside a wall or near curtains or arm-chairs etc. (fig. 3 - 4).
-
ALWAYS face heater towards centre of room. Special care should be taken if the heater is on
a surface where it can move or twist on its wheels or castors if knocked by a child or dog, etc.
-
Minimum Clearance : 200 mm from sides,1500 mm from front.
-
The heater you have purchased is fitted with safety devices which come on in the event
of malfunctioning while the appliance is in use. If the pilot light (placed opposite the
burner) accidentally goes out, or if the room is not sufficiently ventilated, the safety devi-
ce will block the gas flow, causing the heater to go off.
-
Do not use the heater at high altitudes.
Gas leakages
If a leak is suspected, turn off gas at the gas bottle, open the window and air the room. DO
NOT disconnect the pressure regulator. Extinguish all naked lights. Slowly turn the gas on
and brush the connections with soapy water or liquid detergent - a gas leak will form bub-
bles. If a leak is found, turn the gas off and inform your Dealer. DO NOT use the heater
again until it has been inspected by your Dealer. NEVER USE MATCHES TO FIND LEAKS.

RADIANT HEATER

Maximum
Medium
Input
Input
KW
g/h
KW
g/h
4.20
305
2.85
207
WARNINGS
Low
Gas pressure
Input
KW
g/h
1.50
109
28÷30 mbar
3
/h.
(30 m
in living rooms).
3
3
3

Advertisement