• Use this appliance only as described in this instruction manual.
As with any electrical appliance, the instructions aim to cover as many situations as
possible. Caution and common sense should be used when operating and installing
this air conditioner.
• This appliance has been manufactured to cool and dehumidify domestic environ-
ments and must not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in accordance with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorized Repair Service Center.
Unauthorized servicing can be dangerous.
• The appliance is not intended for use by persons (including children) with reduced phys-
ical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If the power cable is damaged, it must be replaced by the manufacturer or an
authorized technical service centre in order to avoid all risk.
• Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any
doubts check with a qualified electrician.
• Do not use extension cables.
• Before cleaning or maintenance operations, always unplug the unit from the outlet.
• Do not pull on or place strain on the power cord when moving the appliance.
• The appliance should not be installed where the atmosphere may contain com-
bustible gases, oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects on the appliance.
• Clean the filters at least once a week.
• Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the
unit at an angle, do not lie it horizontally.
• Before transporting the unit, drain the unit. After transportation, wait at least 6 hours
before switching the unit on.
• The packaging materials can be recycled. You are therefore recommended to
place them in the special containers for differentiated waste collection.
• This appliance is fitted with a special safety device. When the compressor switches
off, this device prevents it from switching on again for at least 3 minutes.
• WARNING: Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
SPECIFIC WARNINGS FOR APPLIANCES WITH R410A REFRIGERANT GAS
R410A refrigerant gas conforms to EC regulations on the environment.
Avoid perforating the refrigerant circuit of the appliance.
ENVIRONMENTAL INFORMATION:
This unit contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Maintenance and disposal must be carried out by qualified personnel only (R410A,
GWP=1975).
THIS PRODUCT IS FOR HOUSEHOLD ONLY
4
Important safeguards
SAVE THESE INSTRUCTIONS
.

Advertisement

Table of Contents
loading

Summary of Contents for DeLonghi PAC C100

  • Page 1 Important safeguards • Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner. •...
  • Page 2: Electrical Connections

    Description DESCRIPTION 9 Power cable 1 Air outlet grille 10 Wall flange (only on some models) 2 Control panel 11 Air exhaust hose 3 Castor wheels 12 Window outlet 4 Handles 13 Castor locks (only on some models) 5 Filter 14 Remote control 6 Air intake grille 15 Window bracket with locking pins...
  • Page 3 For help with installation, operation, accessories spare/replacement parts, Please con- tact our toll free customer service call center at: 1-800-322-3848 [US only] or log onto our website at www.delonghi.com...
  • Page 4: Semi-Permanent Installation

    Semi-permanent installation • Fit the wall flange (10) into the hole. SEMI-PERMANENT INSTALLATION • Fit the air exhaust hose (11) in the rel- If required, your appliance can also be evant housing located on the rear installed semi-permanently (Fig. E). side of the appliance.
  • Page 5: The Control Panel

    Control panel THE CONTROL PANEL DESCRIPTION OF THE CONTROL PANEL A ON/STAND-BY button B MODE selection button: Air conditioning, dehumidifying, fan. C Fan speed selection button (HIGH/MED/LOW/AUTO) D Timer button E Programmed operation increase temperature/time button F Programmed operation decrease temperature/time button G Display Displays the temperature values set and the programmed operating time H Timer in operation indicator light I/L/M/N Fan speed lights and AUTO lights...
  • Page 6: Operation

    Operation TURNING THE APPLIANCE ON Plug into the outlet and check the black cap is fully inserted. Two lines appear on the display indicating that the appliance is in stand-by. Press the ON/STAND-BY button (A). When turned on, the air conditioner starts operating in the same mode as when it was turned off.
  • Page 7: Self-Diagnosis

    Self-diagnosis SELF-DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions. Error messages are displayed on the appliance display. IF ... IS DISPLAYED ...WHAT SHOULD YOU DO? The appliance is fitted with a frost protection device to avoid excessive formation of ice on internal components.
  • Page 8: Description Of The Remote Control

    Using the remote control unit MODELS WITH REMOTE CONTROL • Point the remote control at the receiv- er on the air conditioner. The remote control must be no more than 23 ft (7 MAX 23 ft MAX 7 metres metres) away from the appliance (without obstacles between...
  • Page 9: Turning The Appliance On

    Turning the appliance ON • Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro- vide reasonable protection against harmful interference in a residential installation. •...
  • Page 10: Setting The Timer

    Setting the timer DEHUMIDIFYING MODE (DRY) Ideal to reduce room humidity (spring and autumn, damp rooms, rainy periods, etc). In dehumidifying mode, the appliance selects fan speed automatically. Two arrows on the remote control display indicate “DRY” and “AUTO” respectively. FAN MODE ONLY (FAN) In fan mode, fan speed can be set by pressing the fan button “FAN”...
  • Page 11 Tips • Never obstruct the air intake (6) or To ensure optimal performance from outlet (1) grilles. your portable air conditioner, follow • Minimize the number of heat sources these recommendations: in the room. • close the windows and doors in the room to be air conditioned.
  • Page 12: Cleaning The Air Filters

    Cleaning Before cleaning or maintenance, turn the START OF SEASON CHECKS appliance off by pressing the ON/STAND- Make sure the power cable and plug are BY button (A) or in models with remote undamaged and the outlet is in good control unit, by pressing the ON/OFF but- condition.
  • Page 13: Troubleshooting

    Troubleshooting NOTE: NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit has been on its side, oil needs to return to the compressor to ensure proper function. With- out allowing the unit this time (6-24 hours) the unit may function for only a short time, and then the compressor will break down from lack of oil.
  • Page 14: Technical Specification

    Technical specifications TECHNICAL SPECIFICATION LIMIT CONDITIONS Power supply voltage see rating label Max. absorbed power Room temperature for during air conditioning “ air conditioning 64 ÷ 95°F (18° ÷ 35°C) Refrigerant “ Cooling capacity “ Transport, filling, cleaning, recovery and dis- posal of refrigerant should be performed by a technical service centre appointed by the manufacturer only.
  • Page 15: Limited Warranty

    If repairs become necessary, see contact information below: U.S. Residents: Please contact our toll free hotline at 1-800-322-3848 or log onto our website at www.delonghi.com CANADA Residents: Please contact our toll free hotline at 1-888-335-6644 or log onto our website at www.delonghi.com...